![Grundig GSS SMCIP 402 C Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/grundig/gss-smcip-402-c/gss-smcip-402-c_assembly-instruction-manual_2273298036.webp)
- 36 -
SMCIP 402 C/T
01/14
A
TV
X
+
• Press button
+
twice to descramble a station (indi-
cation "X").
• Press the
MODE
button.
—> Return to the "Input parameter" main menu – "
INPUT
".
• Press the
MODE
button.
—> The "Output data rate" – "
DATARATE
" main menu is activated.
o
utPut
data
r ate
This menu shows the maximum possible output data rate and the current need-
ed output data rate in MBit/s.
OVER
DATARATE
28 / 50.8
OVER
DATARATE
28 / 31.6
OVER
DATARATE
28 / 108
28
: The current needed output data rate.
50.8
: Maximum output data rate DVB-C and ASI at
RF+ASI
mode
(RF+ASI mode; dependent on the output parameter settings).
31.6
: Maximum output data rate DVB-T and ASI at
RF+ASI
mode
(RF+ASI mode; dependent on the output parameter settings).
108
: Maximum output data rate at
ASI
mode (modulator off).
If the station filter is set correctly, the current needed data rate is at least 10%
less than the maximum data rate. The value fluctuates, since the data rates of
individual stations are dynamically modified by the broadcasters.
—> Is the current needed data rate higher than the maximum data rate
"
OVER
" appears in the display. In this case correct the output pa-
rameter settings (DVB-C page 22 / DVB-T page 24) or the settings of the
station selection (page 34).
OVER
DATARATE
75 / 50.8
OVER
DATARATE
75 / 31.6
OVER
DATARATE
112 / 108
• Press the
MODE
button.
—> The "Transport stream ID and ORGNET-ID" – "
TS/ONID
" main
menu is activated.
Содержание GSS SMCIP 402 C