9.11. Schedule
This function allows the users to setup schedules for features including: <Alarm Switch>, <Motion Detection> ,
<Network Failure Detection> and <Profile>. This function supports up to 10 sets of time frames in the time frame
list.
Schedule Setup :
First, you need to set up a schedule and select a time frame from the time frame list. Then please check the
weekday boxes below to choose the specific weekdays. At last, select a time mode, Day mode, Night Mode or Time
mode. Under Time mode, users can specify the start time and the duration time for activation of the schedule
triggered features. The setting range for the duration time is from 00:00 to 168:59. Click on <Save> to save the
setup.
Time Mode :
- Day: this pro
fi
le will be loaded when IR cut is off.
- Night: this pro
fi
le will be loaded when IR cut is on.
- Time: indicates the start time and time duration for the schedule.