![Grundig GCI-F1576V Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/grundig/gci-f1576v/gci-f1576v_owners-manual_2273080063.webp)
- Detection level [1-100]:
The default level is 10. This item is to set the detection level for each sampling pixel; the smaller the value, the
more sensitive the detection is.
- Time interval (sec) [0-7200]:
Here you can set the interval between each detected audio occurrance. The default interval is 10.
Triggered Action (Multi-option) :
The Administrator can specify alarm actions that will take place when the alarm is triggered. All options are
listed as follows:
- Enable Alarm Output:
Check this item and select the predefined type of alarm output to enable alarm relay output when a face is
detected.
- Record Video Clip:
Check this item and select a video recording storage type, <SD Card> or <NAS> (Network-Attached Storage). The
alarm-triggered recording will be saved onto the microSD card or the NAS.
The pre-trigger buffer recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 3 seconds.
Select <Upload for __ sec> to set the recording duration after the alarm is triggered. The setting range is from 1
to 99999 seconds.
Select <Upload while trigger is active> to record the triggered video until the trigger is turned off.
NOTE: Please make sure that local recording (with Micro SD/ SDHC card) or the remote recording (with NAS) is
activated so that this function can be implemented. See section 9.10. Recording for further details.
- Send Message by FTP:
The Administrator can choose to send an alarm message by FTP when an alarm is detected.
The <Pre-trigger buffer> recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 20 frames.
On the other hand, the <Post-trigger buffer> is for uploading a certain amount of images after the alarm input is
triggered. The post-trigger buffer time range is from 1 to 20 frames.
Check the box <Continue image upload> to upload the triggered images during a certain time or keep uploading
until the trigger is off.
- Select <Upload for __sec> and enter the duration in the blank. The images of the duration will be uploaded to
the FTP when the alarm input is triggered. The setting range is from 1 to 9999 seconds.
- Select <Upload while trigger is active> to keep the images being uploaded to the FTP while the trigger is active,
i.e. until the alarm is stopped.
Set the Image frequency as the upload frame rate. The setting range is from 1 frame to 15 frames.
NOTE: Normally, the setting range of the <Pre-trigger buffer> is 1 to 20. However, the setting range will change
accordingly if the frame rate of MJPEG on the <Video Frame Rate> setting page is 6 or smaller.
NOTE: Please make sure that the local recording (with Micro SD/ SDHC card) is activated so that this function can
be implemented. See section 9.10. 'Recording' for further details.
- Send Message by E-Mail:
The Administrator can choose to send an alarm message by E-Mail when an alarm is triggered.