![Grundig GCI-C0735P Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/grundig/gci-c0735p/gci-c0735p_owners-manual_2273076053.webp)
11.3. Auto Pan Programming
The network Speed Dome Camera supports four Auto Pan Paths. Please refer to the instructions below to set an
Auto Pan Path.
Auto Pan Setting :
To set up an Auto Pan Path, please first select a path number from the drop-down list. Then move the cursor to
the live view pane, and move the camera to a desired view as the Start Point of an Auto Pan Path. Click the “Set”
button of the “Start Point”, and the current view will be automatically saved as the start point of the Auto Pan
Path.
NOTE: The room ratio of an Auto Pan’s Start Point will persist throughout the whole path.
Enter the speed ratio into the Speed field; the speed ratio ranges from 0 (low) to 3 (fast). Then choose to run the
Auto Pan Path in right/left direction from the Direction drop-down list.
Move the camera to another desired position as the end point of the Auto Pan Path. Click the “Set” button of the
“End Point” for saving the setting.
Auto Pan Run :
Select the specified Auto Pan Path from the drop-down list, press the “Run” button, and then the camera will
start moving horizontally as recorded.
To view the camera panning in full screen mode, please move the cursor onto the live view pane, right-click and
left-click to select “full screen”. Then users can view the camera navigation in full screen.
To stop running an Auto Pan Path, simply move the cursor to the live view pane and move the camera in any
direction.
51