If the selected function is “Preset”, it is required to enter its dwell time (1 ~ 256 sec.) in the corresponding field as
shown below. When the alarm is triggered, the camera will go to the selected Preset Point and stay there for a
user-defined period of time. As for other function modes, the camera will keep executing the specified function;
to stop the performance, simply change the camera’s status.
NOTE: The dwell time is only adjustable when selecting Preset as the alarm action. When the dwell time is up, the
network Speed Dome Camera will go back to its trigger position and recheck alarm pin status.
File Name :
Enter a file name into the blank box, e.g. image.jpg. The uploaded image’s file name format can be set in this
section. Please select the one that meets your requirements.
- Add date/time suf
fi
x:
File name: imageYYMMDD_HHNNSS_XX.jpg
Y: Year, M: Month, D: Day
H: Hour, N: Minute, S: Second
X: Sequence Number
- Add sequence number suf
fi
x (no maximum value):
File name: imageXXXXXXX.jpg
X: Sequence Number
- Add sequence number suffix up to _ and then start over:
File Name: imageXX.jpg
X: Sequence Number
The file name suffix will end at the number being set. For example, if the setting is “10” the file name will start
from 00, end at 10, and then start all over again.
- Overwrite:
The original image in the FTP site will be overwritten by the new uploaded file with a static filename.
Save :
After completing all the settings mentioned above, please click on the Save button to save all the settings in this
page.