EXIT:
Exit the PRESET menu and go back to MAIN PAGE 2 to set up a sequence.
NOTE: Users can set preset points through a keyboard. Please refer to the control keyboard’s quick guide for
further information.
5.3.13. SEQUENCE
The function executes the pre-positioning of the pan, tilt, zoom and focus features in a certain sequence for a
camera. Before setting this function, users must preset at least two preset points.
SEQUENCE LINE:
Up to
eight sequence lines
can be configured
in th
is
Camera. Please use the LEFT/RIGHT direction keys to
first select a line and then set its sequence points.
SEQUENCE POINT:
Up to 64 points can be set up for each Sequence line. The Sequence Points represent the order of the preset
points that the Dome Camera will automatically run. The following setup items, including Preset Position, Speed
and Dwell Time, will influence how the camera runs through each sequence point.
PRESET POSITION:
Users can assign a specific preset position to the selected Sequence Point with this item. The available options
are from <1> to <255> and <END>. <END> is used for the Sequence Point following the last Sequence Point when
the amount of sequence points (please refer to the previous section) is less than 64 points.
NOTE: If you are not using all 64 points, please set the point following the last Sequence Point as <END> (PRESET
POSITION) so that the sequence line can work properly. For example, if a user intends to set a Sequence Line
with 5 sequence points. It is required to set the PRESET POSITION of Sequence Point 06 as <END>.
SPEED:
Users can set the pan/tilt speed of the Dome Camera from one Sequence Point to the next one. There are steps
from 1 to 15 to define the speed the Dome Camera will use to move to the next Preset. Within this range, the PAN
speed varies from 10 to 400 (degree/sec.), and the TILT speed varies from 8 to 400 (degree/sec.).
DWELL TIME:
The DWELL TIME is the duration time during which the Dome Camera will stay at a Sequence Point, and the
range is from <000> to <127> seconds. The Dome Camera will go to the next sequence point when the DWELL
TIME expires. If the setting is <000>, the Dome Camera will stay at this Sequence Point for less than 1 second and
then shift to the next point.
RUN SEQUENCE:
Users can command the Dome Camera to run the selected Sequence line manually. Press the <CAMERA MENU>
key (ENTER) to execute a sequence line.
EXIT:
Select this item to exit the SEQUENCE menu and go back to MAIN PAGE 2 to set up an Auto Pan.
NOTE: Users can execute the sequence function through a keyboard. Please refer to the control keyboard’s quick