English (US)

2. Symbols used in this document

3.  Product description

3.1 Introduction

Grundfos pumps are carefully inspected and 
tested before shipment. This pump should 
provide long, efficient, trouble-free performance. 
To ensure maximum performance and reliability, 
please follow the simple instructions in this 
manual.
When installing this pump, always follow basic 
safety precautions and any federal, state, and 
local requirements.

3.2 Delivery and handling

Examine the components carefully to make sure 
no damage has occurred to the pump during 
shipment. Take care to ensure the pump is NOT 
dropped or mishandled; dropping will damage 
the pump.

3.3 Pre-installation checklist

Before beginning installation procedures, the 
following checks should be made. They are all 
important for proper installation of the circulator 
pump.

3.3.1 Applications

Model UP(S)15, 26, 43 and 50 series pumps are 
generally designed to circulate water from +32 
°F to +230 °F (0 °C to +110 °C) up to a 
maximum pressure of 150 psi (10 bar). Some 
models have temperature limitations which are 
shown in Table A below. If required, a 50 % by 
volume solution of ethylene or propylene glycol 
and water can be used; however, a decrease in 
pump performance may result due to an 
increase in the viscosity of the solution. Check 
with manufacturer for information regarding 
suitability of pumping other liquids.

Closed systems

Model UP(S) 15, 26, 43 and 50 series pumps 
with cast iron pump housings are designed to 
pump water compatible with their cast iron 
construction. They are recommended for use in 
closed hydronic systems (i.e. airless, non-
potable water).

Open systems

Model UP(S) 15, 26, 43 and 50 series pumps 
with stainless steel or bronze pump housings 
are designed to pump water compatible with 
their construction and can be used in both open 
and closed systems.

3.3.2 Maximum water temperature

The maximum allowable water temperature is 
determined by the ambient or surrounding air 
temperature as shown in Table A.

WARNING

If these safety instructions are not 
observed, it may result in personal 
injury.

WARNING

If these instructions are not observed, 
it may lead to electric shock with 
consequent risk of serious personal 
injury or death.

Caution

CAUTION

If these safety instructions are not 
observed, it may result in malfunction 
or damage to the equipment.

Note

Notes or instructions that make the 
job easier and ensure safe operation.

Содержание UP 15-100F

Страница 1: ...GRUNDFOS INSTRUCTIONS UP Series circulators Installation and operating instructions UP15 and UP26 Stainless and Bronze ...

Страница 2: ...instructions To obtain service under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless otherwise provided the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions...

Страница 3: ... by volume solution of ethylene or propylene glycol and water can be used however a decrease in pump performance may result due to an increase in the viscosity of the solution Check with manufacturer for information regarding suitability of pumping other liquids Closed systems Model UP S 15 26 43 and 50 series pumps with cast iron pump housings are designed to pump water compatible with their cast...

Страница 4: ...tank pool etc Table A Maximum water temperature Ambient temperature 104 F 40 C 120 F 48 C 140 F 60 C 160 F 71 C 175 F 79 C Water temperature All UP 230 F 110 C 220 F 104 C 210 F 98 C 190 F 87 C 175 F 79 C Exceptions below UPS 15 35 165 F 73 C 140 F 60 C UP 15 100F 205 F 96 C 195 F 90 C 185 F 85 C 175 F 79 C UP 26 120U 205 F 96 C 195 F 90 C 185 F 85 C 175 F 79 C UP 26 116 150 F 65 C 140 F 60 C Tabl...

Страница 5: ...es be installed on each side of the pump If possible do not install elbows branch tees and similar fittings just before or after the pump Provide support to the pump or adjacent plumbing to reduce thermal and mechanical stress on the pump 4 3 Installation requirements 1 Thoroughly clean and flush the system prior to pump installation 2 Do not install the pump at the lowest point of the system wher...

Страница 6: ... pumps 5 1 2 Multi speed pump wiring 1 Insert black conductor into terminal L position 2 Insert white conductor into terminal N position 3 Insert grounding conductor into terminal position Fig 4 Wiring diagram for 115 V and 230 V multi speed pumps UP S 15 capacitor wire position 4 8 UP S 26 43 50 capacitor wire position 2 4 WARNING All electrical work should be performed by a qualified electrician...

Страница 7: ...e end of the shaft and gently turn until the shaft moves freely Replace and tighten the plug Open the isolating valves and wait 2 to 3 minutes for the system pressure to equalize before starting the pump 9 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service 2 If this is not possible contact the nearest Grundf...

Страница 8: ... O Box 16768 Jebel Ali Free Zone Dubai Phone 971 4 8815 166 Fax 971 4 8815 136 www grundfos uae GRUNDFOS Canada 2941 Brighton Road Oakville Ontario L6H 6C9 Canada Phone 1 905 829 9533 Telefax 1 905 829 9512 www grundfos ca GRUNDFOS México Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto C P 66600 Apodaca N L México Phone 011 52 81 8144 4000 Fax 011 52 81 8144 4010 www grundfos mx ...

Страница 9: ...ECM 1202189 www grundfos com The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding A S ...

Отзывы: