6. Startup

7. Operation

Grundfos domestic circulator pumps, installed 
properly and sized for correct performance, will 
operate quietly and efficiently and provide years 
of service.

UPS

 model pumps are multispeed, and the 

speed can be changed via a speed selector 
switch located on the front of the terminal box. 

UP

 models are single-speed.

8. Troubleshooting

8.1 Failure to operate

When UP and UPS 15, 26, 43, and 50 pumps 
are first started, the shaft may rotate slowly until 
water has fully penetrated the bearings.
If the pump does not run, the shaft can be 
rotated manually. To accomplish this, switch off 
the power supply, and close the isolation valves 
on each side of the pump. Remove the indicator 
plug in the middle of the nameplate. Insert a 
small flat-blade screwdriver into the end of the 
shaft, and gently turn until the shaft moves 
freely. Replace and tighten the plug. Open the 
isolating valves and wait 2 to 3 minutes for the 
system pressure to equalize before starting the 
pump.

9. Disposal

This product or parts of it must be disposed of in 
an environmentally sound way:
1. Use the public or private waste collection 

service.

2. If this is not possible, contact the nearest 

Grundfos company or service workshop.

Subject to alterations.

Caution

Do not use the pump to vent the 
system.

Caution

Do not start the pump before filling 
the system.

Caution

Never let the pump run dry.

Caution

Under no circumstances should the 
pump be operated without water 
circulation or without the minimum 
required inlet pressure for prolonged 
periods of time.
This could result in motor and pump 
damage.

Note

After a long shutdown period, multi-
speed pumps should be started on 
speed 3 and then adjusted to the 
regular setting.
The UPS 15-42 has an automatic 
function to assist in restarting.

Содержание UP 15-100F

Страница 1: ...GRUNDFOS INSTRUCTIONS UP Series circulators Installation and operating instructions UP15 and UP26 Stainless and Bronze ...

Страница 2: ...instructions To obtain service under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless otherwise provided the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions...

Страница 3: ... by volume solution of ethylene or propylene glycol and water can be used however a decrease in pump performance may result due to an increase in the viscosity of the solution Check with manufacturer for information regarding suitability of pumping other liquids Closed systems Model UP S 15 26 43 and 50 series pumps with cast iron pump housings are designed to pump water compatible with their cast...

Страница 4: ...tank pool etc Table A Maximum water temperature Ambient temperature 104 F 40 C 120 F 48 C 140 F 60 C 160 F 71 C 175 F 79 C Water temperature All UP 230 F 110 C 220 F 104 C 210 F 98 C 190 F 87 C 175 F 79 C Exceptions below UPS 15 35 165 F 73 C 140 F 60 C UP 15 100F 205 F 96 C 195 F 90 C 185 F 85 C 175 F 79 C UP 26 120U 205 F 96 C 195 F 90 C 185 F 85 C 175 F 79 C UP 26 116 150 F 65 C 140 F 60 C Tabl...

Страница 5: ...es be installed on each side of the pump If possible do not install elbows branch tees and similar fittings just before or after the pump Provide support to the pump or adjacent plumbing to reduce thermal and mechanical stress on the pump 4 3 Installation requirements 1 Thoroughly clean and flush the system prior to pump installation 2 Do not install the pump at the lowest point of the system wher...

Страница 6: ... pumps 5 1 2 Multi speed pump wiring 1 Insert black conductor into terminal L position 2 Insert white conductor into terminal N position 3 Insert grounding conductor into terminal position Fig 4 Wiring diagram for 115 V and 230 V multi speed pumps UP S 15 capacitor wire position 4 8 UP S 26 43 50 capacitor wire position 2 4 WARNING All electrical work should be performed by a qualified electrician...

Страница 7: ...e end of the shaft and gently turn until the shaft moves freely Replace and tighten the plug Open the isolating valves and wait 2 to 3 minutes for the system pressure to equalize before starting the pump 9 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service 2 If this is not possible contact the nearest Grundf...

Страница 8: ... O Box 16768 Jebel Ali Free Zone Dubai Phone 971 4 8815 166 Fax 971 4 8815 136 www grundfos uae GRUNDFOS Canada 2941 Brighton Road Oakville Ontario L6H 6C9 Canada Phone 1 905 829 9533 Telefax 1 905 829 9512 www grundfos ca GRUNDFOS México Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto C P 66600 Apodaca N L México Phone 011 52 81 8144 4000 Fax 011 52 81 8144 4010 www grundfos mx ...

Страница 9: ...ECM 1202189 www grundfos com The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding A S ...

Отзывы: