6.3.7 Selection of function for digital input

The digital input of the pump (terminal 1, fig. 5, 8 or 11) can be 
set to different functions. 
Select one of the following functions: 

Min. (min. curve)

Max. (max. curve)

Ext. fault 

(external fault),

Flow switch.

The selected function is activated by closing the contact between 
the following terminals: 
• 1 and 9 of single-phase pumps (fig. 5)
• 1 and 9 of three-phase pumps, 0.75-7.5 kW (fig. 8). 
• 1 and 3 of three-phase pumps, 11-22 kW (fig. 11).
See also section 

7.2 Digital input

.

Min.:

 

When the input is activated, the pump is operating according to 
the min. curve. 

Max.:

 

When the input is activated, the pump is operating according to 
the max. curve. 

Ext. fault:

When the input is activated, a timer is started. If the input is 
activated for more than 5 seconds, the pump is stopped and a 
fault is indicated. If the connection is disconnected for more than 
5 seconds, the fault condition will cease and the pump can be 
restarted manually by resetting the fault indication.
The typical application will be detection of missing inlet pressure 
or water shortage by means of a pressure switch installed on the 
suction side of a pump.

Flow switch:

When this function is active, the pump will be stopped when a 
connected flow switch detects a low flow. 
It is only possible to use this function if the pump is connected to 
a pressure sensor.
When the input is activated for more than 5 seconds, the stop 
function incorporated in the pump will take over, see section

6.3.8 Setting of stop function

6.3.8 Setting of stop function 

When the stop function is active, the pump will be stopped at very 
low flows to avoid unnecessary power consumption.
It is only possible to use this function if the pump is connected to 
a pressure sensor, a non-return valve and a diaphragm tank.
The stop function can be set to:

Active

Not active

.

There are two possibilities of low-flow detection:
1. By means of the built-in "low-flow detector" which automati-

cally starts functioning if no flow switch is chosen/connected to 
the digital input. 

1. The pump will check the flow regularly by reducing the speed 

for a short time, thus checking the change in pressure. If there 
is no or a small change in pressure, the pump will detect a low 
flow.

2. By means of a flow switch connected to the digital input. When 

the input is activated for more than 5 seconds, the stop func-
tion of the pump takes over. Unlike the built-in low-flow detec-
tor, the flow switch measures the minimum flow at which the 
pump must stop. The pump will not check the flow regularly by 
reducing the speed.

When the pump detects a low flow, the speed will be increased 
until the stop pressure (actual se 0.5 x 

Δ

H) is reached and 

the pump stops. When the pressure has fallen to the start 
pressure (actual setpoint – 0.5 x 

Δ

H), the pump will restart.

Fig. 26

Difference between start and stop pressures (

Δ

H)

Δ

H is factory-set to 

5 % of actual setpoint

Δ

H can be set within the range from 5 % to 30 % of actual 

setpoint. 

Pumps without factory-fitted sensor:

 If the non-return valve is 

fitted between pump and diaphragm tank, the pressure sensor 
must be fitted after the non-return valve.

Fig. 27

Position of non-return valve in the system

The stop function requires a diaphragm tank of a certain minimum 
size. The tank must be installed immediately after the pump and 
the precharge pressure must be 0.7 x actual setpoint.
Recommended diaphragm tank size: 

If a diaphragm tank of the above size is installed in the system, 
the factory setting of 

Δ

H is the correct setting.

If the tank installed is too small, the pump will start and stop too 
often. This can be remedied by increasing 

Δ

H. 

TM

00

 77

44

 18

96

Note

The non-return valve must be fitted immediately 
before the pump, fig. 27.

TM

0

0

 7

745

 1

896

 Nominal flow of pump

[m³/h]

Diaphragm tank size

[litres]

0-6

8

7-24

18

25-40

50

41-70

120

71-100

180

Δ

H

Stop pressure

Start pressure

H

Q

Correctly installed
non-return valve

Pump

Diaphragm tank

Grundfos.bk  Page 16  Tuesday, April 17, 2007  8:54 AM

Содержание SPKE

Страница 1: ...CRE CRIE CRNE CRKE SPKE MTRE CHIE 1 3 phase GRUNDFOS INSTRUCTIONS Installation and operating instructions Grundfos bk Page 1 Tuesday April 17 2007 8 54 AM...

Страница 2: ...he defective product must be returned to the distributor or dealer of Grundfos products from which it was purchased together with proof of purchase and installation date failure date and supporting in...

Страница 3: ...Menu STATUS 13 6 2 1 Display of actual setpoint 14 6 2 2 Display of operating mode 14 6 2 3 Display of actual value 14 6 2 4 Display of actual speed 14 6 2 5 Display of input power and power consumpti...

Страница 4: ...secured to a solid foundation by bolts through the holes in the flange or base plate 3 1 Motor cooling To ensure sufficient cooling of motor and electronics the following must be observed Place the p...

Страница 5: ...mp is started stopped via an external on off switch it will start immediately 3 4 Other connections The connection terminals of external potential free contacts for start stop and digital function ext...

Страница 6: ...be marked with the following symbols The leakage current of the motor can be found in section 13 2 Leakage current 3 5 4 Motor protection The pump requires no external motor protection The motor incor...

Страница 7: ...art stop digital function setpoint and sensor signals terminals 1 9 and bus connection terminals B Y A All inputs group 1 are internally separated from the mains conducting parts by reinforced insulat...

Страница 8: ...thermal protection against slow overloading and blocking 3 7 5 Protection against mains voltage transients The pump is protected against mains voltage transients in accordance with EN 61 800 3 3 7 6 S...

Страница 9: ...with screen and wire connection Screws for frame connections must always be tightened whether a cable is fitted or not The wires in the pump terminal box must be as short as possible 3 10 Bus connect...

Страница 10: ...ional possibilities of setting and status displays see section 6 Setting by means of R100 4 3 Factory setting Pumps without factory fitted sensor The pumps have been factory set to uncontrolled operat...

Страница 11: ...rve of the pump bottom light field flashes When the bottom light field is on must be pressed for 3 seconds before the light field starts flashing To return to uncontrolled or controlled operation pres...

Страница 12: ...NSTALLATION 5 1 1 5 1 2 5 1 3 5 2 1 5 2 2 5 2 3 5 2 4 5 2 5 5 2 6 5 3 1 5 3 2 5 3 3 5 3 4 5 3 5 0 GENERAL 5 3 6 5 3 7 5 3 8 5 3 9 5 3 10 5 1 4 5 3 11 Only three phase pumps up to 7 5 kW 1 OPERATION Gr...

Страница 13: ...otor temperature Undervoltage Overvoltage Too many restarts after faults Overload Sensor signal outside signal range Setpoint signal outside signal range External fault Duty standby Communication faul...

Страница 14: ...t be reset 6 2 6 Display of operating hours Tolerance 2 The value of operating hours is an accumulated value and cannot be reset 6 3 Menu INSTALLATION 6 3 1 Selection of control mode The desired perfo...

Страница 15: ...f the following types 0 5 V three phase pumps 11 22 kW only 0 10 V 0 20 mA 4 20 mA Not active If Not active is selected the setpoint set by means of the R100 or on the control panel will apply The set...

Страница 16: ...1 By means of the built in low flow detector which automati cally starts functioning if no flow switch is chosen connected to the digital input 1 The pump will check the flow regularly by reducing th...

Страница 17: ...other pump to the mains supply Using the R100 make the necessary settings in menu OPERATION and INSTALLATION Set the duty standby function to Active The running pump will search for the other pump an...

Страница 18: ...Example At a lower pressure sensor value of 0 bar a setpoint set of 3 bar and an external setpoint of 80 the actual setpoint will be as follows Hactual Hset Hlower x external setpoint Hlower 3 0 x 80...

Страница 19: ...time the pump will operate according to the function with the highest priority The priority of the settings is as shown in the following tables Example If via the digital input the pump has been force...

Страница 20: ...t to stop Perma nently on Off The pump has stopped because of a fault Restarting will be attempted it may be necessary to restart the pump by resetting the fault indication If the cause is external fa...

Страница 21: ...e length 500 m Current signal DC 0 20 mA 4 20 mA Ri 175 Tolerance 0 3 at maximum current signal Screened cable 0 5 1 5 mm 28 16 AWG Maximum cable length 500 m Sensor signals Voltage signal 0 10 VDC Ri...

Страница 22: ...415 V 10 50 60 Hz PE Cable Max 10 mm See nameplate Recommended fuse sizes Standard as well as quick blow or slow blow fuses may be used 15 2 Leakage current Earth leakage current 30 mA The leakage cu...

Страница 23: ...t time use the double quantity of lubricating grease as the lubricating channel is still empty The recommended grease type is Asonic GHY 72 which is a polycarbamide based lubricating grease 17 Disposa...

Страница 24: ...rgy i2t and less let through curent Ip than the max pre fuses listed above can also be used The voltage rating of the fuse and the inverse time circuit breaker must be at least the same voltage rating...

Страница 25: ...25 Grundfos bk Page 25 Tuesday April 17 2007 8 54 AM...

Страница 26: ...26 Grundfos bk Page 26 Tuesday April 17 2007 8 54 AM...

Страница 27: ...ada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 M xico Bombas GRUNDFOS de M xico S A de C V Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto Apoda...

Страница 28: ...w grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L MLE TL 02 4 07 US Repl L MLE TL 02 8 04 Grundfos bk Page 28 Tuesday April 17 2007 8 54 A...

Отзывы: