Original installation and operating instructions.

CONTENTS

Page

1.

Delivery and storage 

4

1.1

Delivery 4

1.2

Storage and handling 

4

2.

General data 

4

2.1

Applications 4

2.2

Pumped liquids 

4

2.3

Sound pressure level 

5

3.

Preparation 5

3.1

Checking of liquid in motor 

5

3.2

Positional requirements 

5

3.3

Diameter of pump/motor 

6

3.4

Liquid temperatures/cooling 

6

4.

Electrical connection 

6

4.1

General 6

4.2

Motor protection 

7

4.3

Lightning protection 

7

4.4

Cable sizing 

7

4.5

Connection of motor 

8

5.

Pump installation

9

5.1

Assembly of motor and pump

9

5.2

Fitting of submersible drop cable 

9

5.3

Riser pipe 

9

5.4

Maximum installation depth below water level

9

5.5

Cable fitting 

10

5.6

Lowering the pump 

10

5.7

Installation depth 

10

6.

Start-up and operation 

10

6.1

Start-up 10

6.2

Operation 10

7.

Maintenance and service

11

8.

Fault finding chart

12

9.

Checking of motor and cable 

13

10.

Disposal

13

These instructions apply to GRUNDFOS submersible motors, 
types MS and MMS, and GRUNDFOS submersible pumps, types 
SP 55, SP 90, SP 270, SP 300 and SP 360, fitted with submersi-
ble motors, types MS or MMS. 

If the pump is fitted with a motor of another motor make than 
GRUNDFOS MS or MMS, please note that the motor data may 
differ from the data stated in these instructions.

1. Delivery and storage 

1.1 Delivery 

GRUNDFOS submersible pumps are supplied from the factory in 
proper packing in which they should remain until they are to be 
installed. 

During unpacking and prior to installation, care must be taken 
when handling the pump to ensure that misalignment does not 
occur due to bending. 

The loose data plate supplied with the pump should be fixed 
close to the installation site. 

The pump should not be exposed to unnecessary impact and 
shocks. 

1.2 Storage and handling 

Storage temperature: Pump: –20°C to +60°C.

Motor: –20°C to +70°C. 

The motors must be stored in a closed, dry and well ventilated 
room.

Note: If MMS motors are stored for more than one year, the shaft 
must be turned by hand at least once a month.
If a motor has been stored for more than one year before installa-
tion, the rotating parts of the motor must be dismantled and 
checked before use.

The pump should not be exposed to direct sunlight. 

If the pump has been unpacked, it should be stored horizontally, 
adequately supported, or vertically to prevent misalignment of the 
pump. Make sure that the pump cannot roll or fall over. During 
storage, the pump can be supported as shown in fig. 1. 

Fig. 1

If the pump is not handled in vertical position, it must be lifted in 
the motor part and the pump part at the same time, see fig. 2. 
Note that the centre of gravity will vary, depending on pump type. 

Fig. 2

1.2.1 Frost protection 

If the pump has to be stored after use, it must be stored on a 
frost-free location, or it must be ensured that the motor liquid is 
frost-proof.

2. General data 

2.1 Applications 

GRUNDFOS submersible pumps, type SP, are designed for a 
wide range of water supply and liquid transfer applications, such 
as the supply of fresh water to private homes or waterworks, 
water supply to nursery gardens or farms, drawdown of ground-
water and pressure boosting, and various industrial jobs. 

The pump must be installed so that the suction interconnector is 
completely submerged in the liquid. The pump can be installed 
either horizontally or vertically, see also section 3.2 Positional 
requirements

2.2 Pumped liquids 

Clean, thin, non-explosive liquids without solid particles or 
fibres.

The maximum sand content of the water must not exceed 
50 g/m³. A larger sand content will reduce the life of the pump and 
increase the risk of blocking. 

When pumping liquids with a density higher than that of water, 
motors with correspondingly higher outputs must be used. 

Note: When pumping liquids with a viscosity and aggressiveness 
higher than that of drinking water, please contact GRUNDFOS.

The maximum liquid temperature appears from section 3.4 Liquid 
temperatures/cooling

Before beginning installation procedures, these 
installation and operating instructions should be 
studied carefully. The installation and operation 
should also be in accordance with local regulations 
and accepted codes of good practice.

T

M

00

 13

49

 24

9

5

T

M

01

 43

49

 01

99

Содержание SP-G

Страница 1: ...SP G GRUNDFOS INSTRUCTIONS Installation and operating instructions ...

Страница 2: ... 60335 1 2002 e EN 60335 2 41 2003 excepto nos pontos 25 1 e 25 8 Bomba com ponta de veio livre A Grundfos declara sob sua única responsabilidade que os produtos SP G aos quais diz respeito esta declaração estão em conformidade com as seguintes Directivas do Conselho sobre a aproximação das legislações dos Estados Membros da CE Directiva Máquinas 2006 42 CE Norma utilizada EN 809 2009 Antes de col...

Страница 3: ...24 Istruzioni di installazione e funzionamento 34 Instrucciones de instalación y funcionamiento 43 Instruções de instalação e funcionamento 52 Οδηγίες εγκατάστασης και λειτουργίας 62 Installatie en bedieningsinstructies 72 Monterings och driftsinstruktion 82 Asennus ja käyttöohjeet 91 Monterings og driftsinstruktion 100 ...

Страница 4: ...e a month If a motor has been stored for more than one year before installa tion the rotating parts of the motor must be dismantled and checked before use The pump should not be exposed to direct sunlight If the pump has been unpacked it should be stored horizontally adequately supported or vertically to prevent misalignment of the pump Make sure that the pump cannot roll or fall over During stora...

Страница 5: ...ith the filling syringe fig 3 until the liquid runs back out of the filling hole 4 Replace the screw in the filling hole and tighten securely before changing the position of the pump Torque 3 0 Nm The submersible pump is now ready for installation Fig 3 3 1 3 Refilling GRUNDFOS submersible motors MMS 6000 MMS 8000 MMS 10000 and MMS 12000 To refill the motor proceed as follows 1 Position the submer...

Страница 6: ...tor makes See motor specifications 4 Electrical connection 4 1 General The electrical connection should be carried out by an authorized electrician in accordance with local regulations The supply voltage rated maximum current and cos appear from the loose data plate that must be fitted close to the installa tion site The required voltage quality for GRUNDFOS MS submersible motors measured at the m...

Страница 7: ...ter must be protected by means of a motor starter with thermal relay or a CU 3 and contactor s GRUNDFOS MMS motors have no built in temperature transmit ter A Pt100 sensor is available as an accessory Motors with a Pt100 sensor must be protected by means of a motor starter with thermal relay or a CU 3 and contactor s Motors without a Pt100 sensor must be protected by means of a motor starter with ...

Страница 8: ... Specific resistance 0 02 mm m q Cross section of submersible drop cable mm sin 0 436 Xl Inductive resistance 0 078 x 10 3 m 4 5 Connection of motor Three phase submersible motors must be protected see section 4 2 Motor protection For electrical connection by means of the CU 3 see the separate installation and operating instructions for this unit When a conventional motor starter is being used the...

Страница 9: ...ightened diagonally to the torques stated in the following table Note Make sure that the pump chambers are aligned when assembly has been completed 5 2 Fitting of submersible drop cable Before fitting the submersible drop cable to the motor make sure that the cable socket is clean and dry To facilitate the fitting of the cable lubricate the rubber parts of the cable plug with non conducting silico...

Страница 10: ...osed off to approx 1 3 of its maximum volume of water Check the direction of rotation as described in section 4 5 1 Checking of direction of rotation If there are impurities in the water the valve should be opened gradually as the water becomes clearer The pump should not be stopped until the water is completely clean as otherwise the pump parts and the non return valve may choke up As the valve i...

Страница 11: ...d at a GRUNDFOS service centre If GRUNDFOS is requested to service the pump GRUNDFOS must be contacted with details about the pumped liquid etc before the pump is returned for service Otherwise GRUNDFOS can refuse to accept the pump for service Possible costs of returning the pump are paid by the customer If a pump has been used for a liquid which is injurious to health or toxic the pump will be c...

Страница 12: ... rotation c The valves in the discharge pipe are partly closed blocked Check and clean replace the valves if necessary d The discharge pipe is partly choked by impurities ochre Clean replace the discharge pipe e The non return valve of the pump is partly blocked Pull out the pump and check replace the valve f The pump and the riser pipe are partly choked by impurities ochre Pull out the pump Check...

Страница 13: ... the full load current there are the following possible faults The contacts of the motor starter burnt Replace the con tacts Poor connection in leads possibly in the cable joint See item 3 Too high or too low supply voltage See item 1 The motor windings are short circuited or partly disjointed See item 3 Damaged pump is causing the motor to be overloaded Pull out the pump for overhaul The resistan...

Страница 14: ... Bride Flangia Brida Flange Φλάντζα Flens Fläns Laippa Flange Motor Motor Moteur Motore Motor Motor Κινητήρας Motor Motor Moottori Motor Direct On Line Starting Direktanlauf Démarrage direct Avviamento diretto Arranque directo Arranque directo Απευθείας Εκκίνηση Directe aanloop Direktstart Suorakäynnistys Direkte start Star Delta Starting Stern Dreieck Anlauf Démarrage étoile triangle Avviamento Y...

Страница 15: ... 3 x 400 V I 40 A L 140 m U 2 Lx L U 140 2 70 m q 25 mm 2 TM00 1346 5092 I 40 A U 2 U 3 x 400 V L 140 m Example U 3 x 380 V I 10 A L 120 m U 2 Lx L U 120 2 60 m q 6 mm 2 TM00 1345 5092 I 10 A U 2 U 3 x 380 V L 120 m ...

Страница 16: ...3 x 220 V I 5 A L 105 m U 3 Lx L U 105 3 35 m q 2 5 mm 2 TM00 1348 5092 I 5 A U 3 U 3 x 220 V L 105 m Example U 3 x 415 V I 100 A L 150 m U 3 Lx L U 150 3 50 m q 50 mm 2 TM00 1347 5092 I 100 A U 3 U 3 x 415 V L 150 m ...

Страница 17: ...112 ...

Страница 18: ...113 ...

Страница 19: ...114 ...

Страница 20: ...ps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFOS Pumps Sdn Bhd 7 ...

Страница 21: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96432078 0711 Repl 96432078 0506 ECM 1078259 ...

Отзывы: