background image

9

Check the direction of rotation as described in section 
4.5.1 Checking of direction of rotation

Fig. 9

If star-delta starting is not required, but direct-on-line starting is, 
the submersible motors should be connected as shown in fig. 10

Fig. 10

4.5.4 Connection in the case of unidentified cable marking/

connection

If it is unknown where the individual leads are to be connected to 
the mains in order to ensure the correct direction of rotation, pro-
ceed as follows: 

Motors wound for direct-on-line starting: 

Connect the pump to the mains as is expected to be right. 

Then check the direction of rotation as described in section 
4.5.1 Checking of direction of rotation

Motors wound for star-delta starting: 

The windings of the motor are determined by means of an ohm-
meter, and the lead sets for the individual windings are named 
accordingly: U1-U2, V1-V2 and W1-W2, see fig. 11

Fig. 11

If star-delta starting is required, the leads should be connected as 
shown in fig. 9. 

If direct-on-line starting is required, the leads should be con-
nected as shown in fig. 10

Then check the direction of rotation as described in section 
4.5.1 Checking of direction of rotation

5. Pump installation

5.1 Assembly of motor and pump

The bolts and nuts securing the straps to the pump must be tight-
ened diagonally to the torques stated in the following table:

The bolts holding the chambers together on pumps types SP 270, 
SP 300 and SP 360 must be tightened to 60 Nm. 

Make sure that the coupling between the pump and motor 
engages properly.

When assembling the motor and the pump, the nuts must be 
tightened diagonally to the torques stated in the following table:

Note: Make sure that the pump chambers are aligned when 
assembly has been completed. 

5.2 Fitting of submersible drop cable 

Before fitting the submersible drop cable to the motor, make sure 
that the cable socket is clean and dry. 

To facilitate the fitting of the cable, lubricate the rubber parts of 
the cable plug with non-conducting silicone paste. 

Tighten the screws holding the cable to the torques stated: 

MS 6000:

 4.0 Nm.

MMS 6000:

 10 Nm.

MMS 12000:

 15 Nm.

5.3 Riser pipe 

If a tool, e.g. a chain pipe wrench, is used when the riser pipe is 
fitted to the pump, the pump must only be gripped by the pump 
discharge chamber.

The threaded joints on the riser pipe must all be well cut and fit 
together to ensure that they do not work loose when subjected to 
torque reaction caused by the starting and stopping of the pump. 

The thread on the first section of the riser pipe which is to be 
screwed into the pump should not be longer than the threads in 
the pump. 

Where flanged pipes are used, the flanges should be slotted to 
take the submersible drop cable and a water indicator hose, if fit-
ted. 

5.4 Maximum installation depth below water level

GRUNDFOS MS 6000:

600 m. 

GRUNDFOS MMS 6000:

200 m. 

GRUNDFOS MMS 8000:

200 m. 

GRUNDFOS MMS 10000:

200 m. 

GRUNDFOS MMS 12000:

200 m. 

TM

00

 13

65 

50

92

T

M

00

 13

66

 50

92

T

M

00

 13

67

 50

92

L2 L3

M

L1

PE

W2 U2

V2

PE

U1

W1

V1

3

L2 L3

M

L1

PE

W2 U2

V2

PE

U1

W1

V1

3

U2

V2

W1W2

U1

V1

Before starting any work on the pump/motor, make 
sure that the electricity supply has been switched off 
and that it cannot be accidentally switched on. 

Pump type

Number of

impellers

Straps 

Bolt/nut

Torque 

[Nm]

 SP 55 / SP 90

10 to 17

M20

180

Pump/motor 

Staybolt diameter 

Torque

[Nm]

M8 18

M10 35

M12 60

M14 95

M16

145

M18

200

Содержание SP-G

Страница 1: ...SP G GRUNDFOS INSTRUCTIONS Installation and operating instructions ...

Страница 2: ... 60335 1 2002 e EN 60335 2 41 2003 excepto nos pontos 25 1 e 25 8 Bomba com ponta de veio livre A Grundfos declara sob sua única responsabilidade que os produtos SP G aos quais diz respeito esta declaração estão em conformidade com as seguintes Directivas do Conselho sobre a aproximação das legislações dos Estados Membros da CE Directiva Máquinas 2006 42 CE Norma utilizada EN 809 2009 Antes de col...

Страница 3: ...24 Istruzioni di installazione e funzionamento 34 Instrucciones de instalación y funcionamiento 43 Instruções de instalação e funcionamento 52 Οδηγίες εγκατάστασης και λειτουργίας 62 Installatie en bedieningsinstructies 72 Monterings och driftsinstruktion 82 Asennus ja käyttöohjeet 91 Monterings og driftsinstruktion 100 ...

Страница 4: ...e a month If a motor has been stored for more than one year before installa tion the rotating parts of the motor must be dismantled and checked before use The pump should not be exposed to direct sunlight If the pump has been unpacked it should be stored horizontally adequately supported or vertically to prevent misalignment of the pump Make sure that the pump cannot roll or fall over During stora...

Страница 5: ...ith the filling syringe fig 3 until the liquid runs back out of the filling hole 4 Replace the screw in the filling hole and tighten securely before changing the position of the pump Torque 3 0 Nm The submersible pump is now ready for installation Fig 3 3 1 3 Refilling GRUNDFOS submersible motors MMS 6000 MMS 8000 MMS 10000 and MMS 12000 To refill the motor proceed as follows 1 Position the submer...

Страница 6: ...tor makes See motor specifications 4 Electrical connection 4 1 General The electrical connection should be carried out by an authorized electrician in accordance with local regulations The supply voltage rated maximum current and cos appear from the loose data plate that must be fitted close to the installa tion site The required voltage quality for GRUNDFOS MS submersible motors measured at the m...

Страница 7: ...ter must be protected by means of a motor starter with thermal relay or a CU 3 and contactor s GRUNDFOS MMS motors have no built in temperature transmit ter A Pt100 sensor is available as an accessory Motors with a Pt100 sensor must be protected by means of a motor starter with thermal relay or a CU 3 and contactor s Motors without a Pt100 sensor must be protected by means of a motor starter with ...

Страница 8: ... Specific resistance 0 02 mm m q Cross section of submersible drop cable mm sin 0 436 Xl Inductive resistance 0 078 x 10 3 m 4 5 Connection of motor Three phase submersible motors must be protected see section 4 2 Motor protection For electrical connection by means of the CU 3 see the separate installation and operating instructions for this unit When a conventional motor starter is being used the...

Страница 9: ...ightened diagonally to the torques stated in the following table Note Make sure that the pump chambers are aligned when assembly has been completed 5 2 Fitting of submersible drop cable Before fitting the submersible drop cable to the motor make sure that the cable socket is clean and dry To facilitate the fitting of the cable lubricate the rubber parts of the cable plug with non conducting silico...

Страница 10: ...osed off to approx 1 3 of its maximum volume of water Check the direction of rotation as described in section 4 5 1 Checking of direction of rotation If there are impurities in the water the valve should be opened gradually as the water becomes clearer The pump should not be stopped until the water is completely clean as otherwise the pump parts and the non return valve may choke up As the valve i...

Страница 11: ...d at a GRUNDFOS service centre If GRUNDFOS is requested to service the pump GRUNDFOS must be contacted with details about the pumped liquid etc before the pump is returned for service Otherwise GRUNDFOS can refuse to accept the pump for service Possible costs of returning the pump are paid by the customer If a pump has been used for a liquid which is injurious to health or toxic the pump will be c...

Страница 12: ... rotation c The valves in the discharge pipe are partly closed blocked Check and clean replace the valves if necessary d The discharge pipe is partly choked by impurities ochre Clean replace the discharge pipe e The non return valve of the pump is partly blocked Pull out the pump and check replace the valve f The pump and the riser pipe are partly choked by impurities ochre Pull out the pump Check...

Страница 13: ... the full load current there are the following possible faults The contacts of the motor starter burnt Replace the con tacts Poor connection in leads possibly in the cable joint See item 3 Too high or too low supply voltage See item 1 The motor windings are short circuited or partly disjointed See item 3 Damaged pump is causing the motor to be overloaded Pull out the pump for overhaul The resistan...

Страница 14: ... Bride Flangia Brida Flange Φλάντζα Flens Fläns Laippa Flange Motor Motor Moteur Motore Motor Motor Κινητήρας Motor Motor Moottori Motor Direct On Line Starting Direktanlauf Démarrage direct Avviamento diretto Arranque directo Arranque directo Απευθείας Εκκίνηση Directe aanloop Direktstart Suorakäynnistys Direkte start Star Delta Starting Stern Dreieck Anlauf Démarrage étoile triangle Avviamento Y...

Страница 15: ... 3 x 400 V I 40 A L 140 m U 2 Lx L U 140 2 70 m q 25 mm 2 TM00 1346 5092 I 40 A U 2 U 3 x 400 V L 140 m Example U 3 x 380 V I 10 A L 120 m U 2 Lx L U 120 2 60 m q 6 mm 2 TM00 1345 5092 I 10 A U 2 U 3 x 380 V L 120 m ...

Страница 16: ...3 x 220 V I 5 A L 105 m U 3 Lx L U 105 3 35 m q 2 5 mm 2 TM00 1348 5092 I 5 A U 3 U 3 x 220 V L 105 m Example U 3 x 415 V I 100 A L 150 m U 3 Lx L U 150 3 50 m q 50 mm 2 TM00 1347 5092 I 100 A U 3 U 3 x 415 V L 150 m ...

Страница 17: ...112 ...

Страница 18: ...113 ...

Страница 19: ...114 ...

Страница 20: ...ps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava ielā 60 LV 1035 Rīga Tālr 371 714 9640 7 149 641 Fakss 371 914 9646 Lithuania GRUNDFOS Pumps UAB Smolensko g 6 LT 03201 Vilnius Tel 370 52 395 430 Fax 370 52 395 431 Malaysia GRUNDFOS Pumps Sdn Bhd 7 ...

Страница 21: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96432078 0711 Repl 96432078 0506 ECM 1078259 ...

Отзывы: