PRE-INSTALLATION

Before beginning installation procedures, these  
installation and operating instructions should be 
studied carefully. The installation and operation  
should  also  be  in  accordance  with  local  regula-
tions and accepted codes of good practice.

The  sound  pressure  level  of  the  BMQE  is  <74  db[A]  at  a 
distance of 3 feet (1 meter). 

It is recommended by Grundfos 

that  the  pump  be  installed  with  sound  and  vibration 
dampening  equipment  such  as;  flexible  piping  adapters 
and  anti-vibration  mounting.  The  pump  should  not  be 
mounted  in  or  adjacent  to  living  quarters. The  pump  can 
also be wrapped with sound proofing insulation to reduce 
noise.  (See page 16, EZ Boost System Diagram.)

1. A guide to the EZ Boost System

The  EZ  Boost  Constant  Pressure  System  automatically 
balances  water  surges  and  equalizes  flow  and  pressure 
according  to  consumption.  In  other  words,  the  system 
maintains  a  constant  water  pressure  in  spite  of  varying 
water  consumption.  The  pressure  is  registered  by  means 
of  the  pressure  sensor  and  transmitted  to  the  controller. 
The controller adjusts the EZ Boost BMQE pump perform-
ance accordingly. The EZ Boost Constant Pressure System 
features:

•  Quick and easy installation: ready-to-use system  

 

 

requiring minimum space

•  High user convenience: constant pressure regardless of  
 

water consumption

•  Easily adjustable pressure level: push button control
•  Continuous control and monitoring of pump operation
•  Integrated dry-running protection
•  Integrated overload protection
•  Integrated protection against over voltage and under  
 

voltage

•  Soft start system

1.1 Function

When  a  tap  is  opened,  the  pressure  in  the  tank  will  start 
to drop. The system maintains a constant pressure within 
the maximum pump performance in spite of varying water 
consumption.

The pressure is registered by means of the pressure sensor, 
which  transmits  a  signal  to  the  controller.  The  controller 
adjusts  the  pump  performance  accordingly  to  maintain 
constant pressure by changing the pump speed.

At low flow the pressure will drop slowly. When the pres-
sure in the tank is 7 PSI below the setpoint, the pump will 

start.  When  the  pressure  is  7  PSI  above  the  setpoint,  the 
pump will stop. 

Even though the EZ Boost controller is controlling the pres-
sure within ±3 PSI, larger pressure variations may occur in 
the  system.  If  the  consumption  is  suddenly  changed,  e.g. 
if  a  tap  is  opened,  the  water  must  start  flowing  before 
the  pressure  can  be  made  constant  again.  Such  dynamic 
variations  depend  on  the  pipe  work,  but,  typically,  they 
will lie between 7 and 14 PSI. If the desired consumption is 
higher than the quantity the pump is able to deliver at the 
desired  pressure,  the  pressure  follows  the  pump  curve  as 
illustrated in the far right of fig. 1.

     Fig. 1

At large flow rates, the pressure will drop quickly and the 
pump will start immediately and maintain constant pres-
sure. When the system is running, the EZ Boost controller 
makes small adjustments to the pressure to detect whether 
there is consumption. If there is none, the pump will simply 
refill the tank and stop after a few seconds.

1.2  Power line communication

The  communication  between  the  EZ  Boost  controller  and 
the  EZ  Boost  BMQE  pump  is  via  the  power  supply  cable. 
This communication principle is known as power line com-
munication. Using this principle means that no additional 
cables  to  the  pump  are  required.  The  communication  of 
data  is  effected  by  means  of  a  high-frequency  signal 
transmitted to the power supply cable. 

In situations where 

multiple EZ Boost BMQE pump power cables are run paral-
lel in wiring trays or conduit and less than 12 inches apart, 
the possibility for undesired communication between units 
exists.

  When  this  occurs,  intermittent  or  continuous  NO 

CONTACT  is  typically  seen.  Other  unexpected  errors  may 
also be seen.

There  are  two  ways  to  eliminate  the  possibility  of  cross 
communication:

Pressure

Flow

A

Stop

+7 PSI

Start 

-7 PSI

Controlling 
±3 PSI

Dynamic 
variations 
±7 PSI 

GPM

0.8

A = Pressure setting

Содержание EZ Boost

Страница 1: ...GRUNDFOS INSTRUCTIONS EZ BoostTM System USA Installation and operating instructions Please leave these instructions with the pump for future reference...

Страница 2: ...a Operating Conditions 6 Storage 6 Frost Protection 6 6 Installation Electrical Connection 6 Cable Sizing 7 Positioning 7 Controller Connection 7 Pressure Sensor 8 Pressure Tank 8 Pressure Relief Valv...

Страница 3: ...e controller adjusts the pump performance accordingly to maintain constant pressure by changing the pump speed At low flow the pressure will drop slowly When the pres sure in the tank is 7 PSI below t...

Страница 4: ...V or rises above 280 V With a rated voltage of 110 115 V 60 Hz the pump will be cut out if voltage falls below 75 V or rises above 150 V The motor is automatically cut in when the voltage is again wi...

Страница 5: ...am The EZ Boost Constant Pressure System should consist of Pos 1 EZ Boost BMQE pump 2 EZ Boost controller 3 Diaphragm tank recommended size 2 U S gallons 8 liter 130 psi 2 3 4 1 5 6 6 Additional boost...

Страница 6: ...and when installed in the vertical position the air vent must be at the top of the unit Insert BMQE pump into the open mounting bracket Secure mounting brackets Apply pressure to the BMQE pump until t...

Страница 7: ...Consult Troubleshooting Section 11 Verify that EZ Boost controller is operating 11 Verify EZ Boost controller is operating These lights are on These lights are on 12 Optional Lock the buttons 12 Opti...

Страница 8: ...f button on the EZ Boost con troller must not be used as a safety switch when installing and servicing the pump Rain tight or wet location hubs that comply with the requirements in the standard for Fi...

Страница 9: ...System 6 1 2 Cable sizing Single phase 60 HZ maximum cable length motor service to entrance Motor rating Copper wire size AWG Volts HP 14 12 10 Maximum cable length ft m 115 0 50 100 30 5 160 48 8 250...

Страница 10: ...signed to work with a 2 gal diaphragm tank Install a diaphragm tank to insure that the BMQE will shut off at zero flow The diaphragm tank must be installed at some point between the BMQE pump and the...

Страница 11: ...um flow for BMQE pumps in parallel will exceed 35 GPM a 4 gallon or two 2 gallon dia phragm tank s should be used 6 9 Generator Operation Power may be supplied to BMQE pumps by an adequately sized gen...

Страница 12: ...on the EZ Boost controller face the pipe shows run lights when the pump is operat ing When the pump is not operating none of the flow indicator lights are on see fig 7 Fig 7 7 2 3 Pressure setting Th...

Страница 13: ...d pressure drops causing the motor to increase speed If the power consumption falls below the dry run setting for an accumulated time of 5 seconds and the motor speed is within 1000 rpm of the max spe...

Страница 14: ...eed Sensor defective Overload Over temperature Speed reduction Voltage alarm No contact to pump see Fig 14 Flashing green light when the pump control is working correctly Permanent yellow light when t...

Страница 15: ...2 Parts list for SQE with instructions for dismantling and assembly of pump and motor 8 2 EZ Boost Controller Service Before starting any work on the EZ Boost con troller make sure that the electricit...

Страница 16: ...and repair replace the pump e Leakage in the pipe work Check and repair the pipe work f Under voltage has occurred Check the electricity supply 4 Frequent starts and stops a The supply voltage is unst...

Страница 17: ...sure sensor If the pump has not started yet proceed as follows Press the on off button for 5 seconds If the pump starts the EZ Boost controller or the sensor may be defective Note The pressure is not...

Страница 18: ...motor communication part is defective Reduce the length of the pump cable Switch off the main power supply to the EZ Boost controller Switch on the main power supply again The pump is now connected d...

Страница 19: ...ording to the values in Section 5 Note As the voltage is detected at the motor allow for the voltage drop in the pump cable 8 The EZ Boost controller indicates Dry running If the power consumption is...

Страница 20: ...ed Replace pump or motor 13 The EZ Boost controller indicates Sensor defective a The pressure sensor is defective Check that the sensor is wired correctly If the sensor type is 4 20 mA measure the DC...

Страница 21: ...faults Poor connection in leads possibly in the cable joint Too low supply voltage see item 1 9 Factory settings Alarm 200 240 V motors 100 115 V motors SQ SQE SQE NE 03A and 05A models SQ SQE SQE NE...

Страница 22: ...4 54 7 8 0 95 2 2 9 15 0 5 5 55 5 8 1 96 0 2 9 15 7 5 5 56 2 8 1 96 7 3 0 16 5 5 6 57 0 8 2 97 5 3 0 17 2 5 6 57 7 8 2 98 2 3 1 18 0 5 7 58 5 8 3 99 0 3 1 18 7 5 7 59 2 8 3 99 7 3 2 19 5 5 8 60 0 8 4...

Страница 23: ...ce under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date failur...

Страница 24: ...Road Oakville Ontario L6H 6C9 Telephone 905 829 9533 Fax 905 829 9512 Bombas Grundfos de Mexico S A de C V Boulevard TLC 15 Parque Stiva Aeropuerto Apodaca N L 66600 Mexico Telephone 52 81 8144 4000 F...

Отзывы: