8.4. EZ Boost controller fault finding chart (continued)

Fault

Possible Cause

Remedy

6.  Even AFTER replacement, the EZ Boost 
 

controller indicates “No contact to 

 

pump”.

a)  Numbering of BMQE pump and 
 

EZ Boost controller is different.

•  If an BMQE/ EZ Boost controller system 
 

has been given a number, this number 

 

is stored in both the BMQE and EZ Boost 

 

controller.

 

A new EZ Boost controller or BMQE 

 

may not have a number corresponding 

 

to the number stored in the previous 

 

unit. Therefore, “No contact to pump” 

 

is indicated even if there is no fault. 

 

Give the new system the number used 

 

in the previous unit in order to obtain 

 

correspondence between the number- 

 

ing of the BMQE pump and the EZ Boost 

 

controller. This requires an R100.

 

Note: 

Two systems on the same main 

 

power supply must not have the same 

 

number!

7.  The EZ Boost controller indicates 
 

“Over voltage” or “Under voltage”.

a)  The supply voltage is unstable or 
 

outside the voltage range specified for 

 

the installed motor type.

•  Check:
 

Possibly over a period of time - that the 

 

supply voltage is according to the values 

 

in Section 5.

 

Note:

 As the voltage is detected at 

 

the motor, allow for the voltage drop in 

 

the pump cable.

8.  The EZ Boost controller indicates 
 

“Dry running”.

If the power consumption is lower than the dry-running stop setting and the motor speed 
is within 1000 rpm of programmed maximum speed, for an accumulated period of 5 sec-
onds, the pump will be stopped.

a)  The pump performance is too high for 
 

the inlet yield.

b)  The well screen is blocked.

•  Replace the pump with a smaller 
 

pump or reduce the pump performance, 

 

by lowering maximum speed, or 

 

reducing set pressure.

•  Check the well capacity and restore 
 

water supply to the well.

9. The EZ Boost controller indicates “Speed 
reduction” and “Under voltage”.

Speed reduction is activated so as to maintain a reduced performance. When the supply 
voltage falls so low that it can no longer supply the necessary current to maintain 3,000 
rpm, the pump will be stopped.

a)  The supply voltage is unstable or lower 
 

than the voltage range specified for the 

 

installed motor type.

b)  The pump is not of the correct type.
c)  The voltage drop in the pump cable is 
 

too great.

•  Restore correct supply voltage.

•  Install correct pump type.
•  Replace the pump cable with lower 
 

gauge wires or reduce cable length.

(continued next page)

17

Содержание EZ Boost

Страница 1: ...GRUNDFOS INSTRUCTIONS EZ BoostTM System USA Installation and operating instructions Please leave these instructions with the pump for future reference...

Страница 2: ...a Operating Conditions 6 Storage 6 Frost Protection 6 6 Installation Electrical Connection 6 Cable Sizing 7 Positioning 7 Controller Connection 7 Pressure Sensor 8 Pressure Tank 8 Pressure Relief Valv...

Страница 3: ...e controller adjusts the pump performance accordingly to maintain constant pressure by changing the pump speed At low flow the pressure will drop slowly When the pres sure in the tank is 7 PSI below t...

Страница 4: ...V or rises above 280 V With a rated voltage of 110 115 V 60 Hz the pump will be cut out if voltage falls below 75 V or rises above 150 V The motor is automatically cut in when the voltage is again wi...

Страница 5: ...am The EZ Boost Constant Pressure System should consist of Pos 1 EZ Boost BMQE pump 2 EZ Boost controller 3 Diaphragm tank recommended size 2 U S gallons 8 liter 130 psi 2 3 4 1 5 6 6 Additional boost...

Страница 6: ...and when installed in the vertical position the air vent must be at the top of the unit Insert BMQE pump into the open mounting bracket Secure mounting brackets Apply pressure to the BMQE pump until t...

Страница 7: ...Consult Troubleshooting Section 11 Verify that EZ Boost controller is operating 11 Verify EZ Boost controller is operating These lights are on These lights are on 12 Optional Lock the buttons 12 Opti...

Страница 8: ...f button on the EZ Boost con troller must not be used as a safety switch when installing and servicing the pump Rain tight or wet location hubs that comply with the requirements in the standard for Fi...

Страница 9: ...System 6 1 2 Cable sizing Single phase 60 HZ maximum cable length motor service to entrance Motor rating Copper wire size AWG Volts HP 14 12 10 Maximum cable length ft m 115 0 50 100 30 5 160 48 8 250...

Страница 10: ...signed to work with a 2 gal diaphragm tank Install a diaphragm tank to insure that the BMQE will shut off at zero flow The diaphragm tank must be installed at some point between the BMQE pump and the...

Страница 11: ...um flow for BMQE pumps in parallel will exceed 35 GPM a 4 gallon or two 2 gallon dia phragm tank s should be used 6 9 Generator Operation Power may be supplied to BMQE pumps by an adequately sized gen...

Страница 12: ...on the EZ Boost controller face the pipe shows run lights when the pump is operat ing When the pump is not operating none of the flow indicator lights are on see fig 7 Fig 7 7 2 3 Pressure setting Th...

Страница 13: ...d pressure drops causing the motor to increase speed If the power consumption falls below the dry run setting for an accumulated time of 5 seconds and the motor speed is within 1000 rpm of the max spe...

Страница 14: ...eed Sensor defective Overload Over temperature Speed reduction Voltage alarm No contact to pump see Fig 14 Flashing green light when the pump control is working correctly Permanent yellow light when t...

Страница 15: ...2 Parts list for SQE with instructions for dismantling and assembly of pump and motor 8 2 EZ Boost Controller Service Before starting any work on the EZ Boost con troller make sure that the electricit...

Страница 16: ...and repair replace the pump e Leakage in the pipe work Check and repair the pipe work f Under voltage has occurred Check the electricity supply 4 Frequent starts and stops a The supply voltage is unst...

Страница 17: ...sure sensor If the pump has not started yet proceed as follows Press the on off button for 5 seconds If the pump starts the EZ Boost controller or the sensor may be defective Note The pressure is not...

Страница 18: ...motor communication part is defective Reduce the length of the pump cable Switch off the main power supply to the EZ Boost controller Switch on the main power supply again The pump is now connected d...

Страница 19: ...ording to the values in Section 5 Note As the voltage is detected at the motor allow for the voltage drop in the pump cable 8 The EZ Boost controller indicates Dry running If the power consumption is...

Страница 20: ...ed Replace pump or motor 13 The EZ Boost controller indicates Sensor defective a The pressure sensor is defective Check that the sensor is wired correctly If the sensor type is 4 20 mA measure the DC...

Страница 21: ...faults Poor connection in leads possibly in the cable joint Too low supply voltage see item 1 9 Factory settings Alarm 200 240 V motors 100 115 V motors SQ SQE SQE NE 03A and 05A models SQ SQE SQE NE...

Страница 22: ...4 54 7 8 0 95 2 2 9 15 0 5 5 55 5 8 1 96 0 2 9 15 7 5 5 56 2 8 1 96 7 3 0 16 5 5 6 57 0 8 2 97 5 3 0 17 2 5 6 57 7 8 2 98 2 3 1 18 0 5 7 58 5 8 3 99 0 3 1 18 7 5 7 59 2 8 3 99 7 3 2 19 5 5 8 60 0 8 4...

Страница 23: ...ce under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date failur...

Страница 24: ...Road Oakville Ontario L6H 6C9 Telephone 905 829 9533 Fax 905 829 9512 Bombas Grundfos de Mexico S A de C V Boulevard TLC 15 Parque Stiva Aeropuerto Apodaca N L 66600 Mexico Telephone 52 81 8144 4000 F...

Отзывы: