5. Identification
5.1 Nameplates
The pump and motor nameplates are positioned on
the motor fan cover or terminal box.
The data and information on the pump nameplate
are described in the table below. See the nameplate
in fig. 6 on page 15.
The data and information on the motor nameplate
are described in the table below. See the nameplate
in fig. 7 on page 15.
6. Mechanical installation
Before installing the pump, check that the pump type
and parts are as ordered.
6.1 Installation of pump
The pump must be installed with the motor shaft
vertical. It must be mounted on a plane surface and
secured by foundation bolts.
The pump should be installed so that the suction
pipe is as short and the suction lift as small as
possible.
The pump should be sited in a well ventilated but
frost-free position. See section
.
The pump may be sited outdoors, but it should be
protected from the elements by means of a suitable
cover.
The pump should be installed with easy access for
inspection, maintenance and service.
6.2 Pipework
It is advisable to fit isolating valves on either side of
the pump. It is thus not necessary to drain the
system if the pump needs service. If the pump is
installed above the liquid level, a non-return valve
must be fitted in the suction pipe below the liquid
level.
The pump must not be stressed by the pipework.
The pipework must be correctly sized taking due
account of the pump inlet pressure.
If the pump is installed at the lowest point of the
system, impurities and sludge may accumulate in the
pump.
Install the pipes so that air locks are avoided,
especially on the suction side of the pump.
See fig. 1.
Fig. 1
Pipework
Pos.
Description
1
Pump type
2
Pump model
3
Maximum ambient temperature
[°C] / [°F]
4
Temperature class
5
Minimum efficiency index
6
Maximum system pressure
[bar] / [psi] / [MPa]
7
Maximum liquid temperature
[°C] / [°F]
8
Hydraulic pump efficiency at best
efficiency point
9
Insulation class
10
Motor protection
11
Rated flow [m
3
/h] / [GPM]
12
Head at rated flow [m] / [psi]
13
Maximum head [m] / [psi]
Pos.
Description
1
Motor designation
2
Number of poles
3
Number of phases and voltage [V]
4
Rated current [A]
5
Power output [kW]
6
Power output [HP]
7
Three-phase pumps only
Motor efficiency [%]
8
Single-phase pumps only
Capacitor size [
μ
F] and voltage [V]
9
CE mark
10
TR mark
11
IE2 mark
12
Company name and address
13
Country of manufacture
TM
01 671
0 329
9
Pos. Description
Function
1
Expansion joint
Reduces noise and
absorbs vibrations and
expansion.
2
Isolating valve
Enables easy service of
the pump.
3
Pipe support
Supports pipe and
absorbs distortion and
strain.
1
2
3