Instruments not allowed:
Note: The use of the following instruments is not allowed during fault
finding:
Note: When measuring, use RMS-instruments.
Checking the motor and cable:
Environment
During handling, operation, storage and transport, all environment
regulations dealing with the handling of hazardous materials must be
observed.
When the pump is taken out of operation, it must be ensured
that no hazardous material is left in the pump and in the riser
pipe, which can be injurous to persons and the environment.
Disposal
Disposal of this product or parts of it must be carried out according to the
following guidelines:
1. Use the local public or private waste collection service.
2. If such waste collection service does not exist or cannot handle the
materials used in the product, please deliver the product or any
hazardous materials from it to your nearest GRUNDFOS company or
service center.
Technical Data
Insulation
Test
Resistance
Test
High-voltage
Test
Measure the voltage L1
(RMS) between phase
and L2. Connect the
voltmeter to the terminals
at the connections.
The voltage should, when the
motor is loaded, be within the
range specified on Page 4, large
variations in supply voltage
indicate poor electricity supply,
and the pump should be stopped
until the problem has been
corrected.
Measure the current (RMS)
while the pump is operating
at a constant discharge
head(if possible, at capacity
where the motor is heavily
loaded). For maximum
current, see motor
nameplate.
If the current exceeds the full load
current, there are the following
possible faults:
Poor connection in the leads,
possibly in the cable joint.
Too low supply voltage, see item 1
on Page 13.
Page 15
Page 16
s
upply Voltage:
1x200-240V +6%/-10%, 50/60 Hz, PE
Operation via Generator:
As a minimum, the generator output
must be equal to the motor P1[KW] +10%
Starting Current:
The motor starting current is equal to the
highest value stated on the motor nameplate
Starting:
Soft starting
Run-up Time:
Maximum : 2 seconds
Motor Protection:
The motor is protected against:
Dry running, overvoltage, undervoltage,
overload, overtemperature
Power Factor:
PF= 1
Service Factor:
0.33-0.50A[HP]-1.75 at 230V
0.50-0.75A[HP]-1.4 at 230V
1.0 -1.5C[HP] -1.15 at 230V
Motor Cable:
3 Wire, 12 AWG TEFZEL
Length
Available in 5 ft. increments from 25ft.- 300ft.
Motor Liquid:
Type SML 2
pH Values:
Redi-Flo3: 5 to 9
Liquid Temperature:
The temperature of the pumped liquid must
not exceed 104°F.
Note: if liquids with a viscosity higher than that of water are to be pumped,
please contact GRUNDFOS
Discharge Port:
5SQE-NE- 1"NPT
10-15SQE-NE- 1 1/4" NPT
22-30SQE-NE- 1 1/2" NPT
STORAGE CONDITIONS
Minimum Ambient Temperature:
-4°F
Maximum Ambient Temperature:
+140°F
Freeze Protection:
If the pump has to be stored after use, it
must be stored on a frost-free location or it
must be ensured that the motor liquid is
frost-proof. (The motor must be stored
without being filled with motor liquid.)
OPERATING CONDITIONS
Minimum Ambient Fluid Temperature:
34°F
Maximum Ambient Fluid Temperature:
+104°F
APPROXIMATE DIMENSIONS AND WEIGHT
Motor Dimensions (MSE3-NE):
0.33-0.50A[hp]
20.9" length x 2.68" diameter
0.50-0.75B[hp]
20.9" length x 2.68" diameter
1.0-1.5C[hp]
22.3" length x 2.68" diameter
Motor Weights (MSE3-NE):
0.33-0.50A[hp]
6.0 Lbs
0.50-0.75B[hp]
7.1 Lbs
1.0-1.5C[hp]
8.2 Lbs
Pump End Dimensions:
Pump Diameter:
2.68"
Pump Diameter, incl. cable guard:
2.91"
Pump End Dimensions(min. and max.):
5SQE-NE
8.1" to 13.6"
10SQE-NE
8.1" to 14.5"
15SQE-NE
8.1" to 14.5"
22SQE-NE
8.1" to 14.5"
30SQE-NE
8.1" to 11.3"
Pump End Weights(min. and max.):
All Redi-Flo3 Models
2.2 lbs to 3.5 lbs
Well Diameter (minimum):
3"
Installation Depth (Maximum):
500 feet, below static water level.
Troubleshooting