background image

We understand water. 

 

 

 

Water softener 

|

 softliQ:MD 

Operation manual 

 

 

Содержание softliQ:MD Series

Страница 1: ...We understand water Water softener softliQ MD Operation manual...

Страница 2: ...operation manual Without the written consent of Gr nbeck Wasseraufbereitung GmbH no part of this manual may be reproduced in any way nor may any part be processed duplicated or distributed using elec...

Страница 3: ...up 25 5 1 How to start up the product 25 5 2 Handing over the product to the owner user 31 6 Operation 32 6 1 Touch display 32 6 2 Menu structure 36 6 3 Connection to Gr nbeck Cloud 39 6 4 Refilling...

Страница 4: ...l safety as well as to avoid damage to property This symbol identifies information and instructions that you must comply with in order to avoid damage to property This symbol identifies important info...

Страница 5: ...ction Handling instruction multi step and chronological sequence of action steps important 1 First action a first step b second step 2 Second action Result after a handling instruction Result Lists Li...

Страница 6: ...available whenever necessary Item Designation Item Designation 1 Observe operation manual 2 Disposal information 3 SVGW test mark 4 DVGW test mark 5 CE mark 6 Nominal pressure 7 Operating pressure 8 A...

Страница 7: ...pply Safety devices must never be removed bridged or otherwise tampered with Do not operate any products which have a damaged power supply cable This can lead to injuries due to electric shock Have da...

Страница 8: ...llowing regulations and directives amongst others during installation start up and maintenance Statutory regulations on environmental protection Provisions of the employers liability insurance compani...

Страница 9: ...ct explained to you by the specialist installer Only perform activities described in this manual Do not carry out any activities that are explicitly marked for a specialist installer Only use this pro...

Страница 10: ...king water The softliQ water softener protects water pipes and connected water carrying systems from scaling or from malfunctions and damage caused by scaling The water softener softliQ MD32 is design...

Страница 11: ...ing valve 5 Control display 6 Brine tank lid 7 Salt supply display sensor 8 Illuminated LED ring 9 Cover for connections customer interface 10 Water connection pipes 11 Housing of technical equipment...

Страница 12: ...is reaction is called ion exchange The calcium and magnesium ions are retained in the exchanger Soft water without calcium and magnesium ions but containing sodium ions leaves the exchanger This proce...

Страница 13: ...required during the regeneration process non softened water is available During each regeneration only the used up system capacity is regenerated and only as much salt is used as necessary No later th...

Страница 14: ...d setting the illuminated LED ring behaves as follows Is illuminated during water treatment Is illuminated during operation of the control unit Intermittent flashing in case malfunctions do occur Inte...

Страница 15: ...ase contact your local Gr nbeck representative or Gr nbeck s headquarters in Hoechstaedt for details Image Product Order no Dosing computer EXADOS EK 6 115 100 Dosing computer EXADOS ES 6 115 200 Elec...

Страница 16: ...ssional installation acc to DIN EN 1717 Extension set for connection hoses DN25 MD32 187 860e Extension kit for connection hoses DN32 MD38 187 680e To extend the hose to 1 6 m 90 connection angle 1 2...

Страница 17: ...s 3 iQ Comfort 2 for networking Gr nbeck products 4 Water sensor digital input If another function is required for the digital input the water sensor must be disconnected Cables LiYY 2x0 5 mm or compa...

Страница 18: ...scription Item Description 1 Protection against contact 2 Fault signal contact upper two terminals max 230 V max 1 A factory setting N C 3 Programmable output lower two terminals e g connection of the...

Страница 19: ...ller should install these systems Item Description Item Description 1 Safety device protectliQ 2 Drinking water filter pureliQ KD 3 Garden water pipe 4 Water withdrawal point 5 EXADOS dosing computer...

Страница 20: ...r filter and if required a pressure reducer e g fine filter pureliQ KD upstream of the product A shock proof socket is required within a distance of approx 1 2 m of the system The socket requires a pe...

Страница 21: ...of supply Item Description Item Description 1 Water softener completely pre assembled 2 2 Connection hoses 3 Water test kit total hardness 4 Operation manual 5 Connection block incl 2 inserts 2 union...

Страница 22: ...open the two valves on the connection block during start up Only carry out the leakage test during start up 4 3 1 Installing connection block 1 Install the water meter screw connection into the pipe 2...

Страница 23: ...both the screws at the side on the upper part of the housing for technical equipment 2 Remove the upper part of the housing for technical equipment 3 Observe the flow direction indicated by arrows on...

Страница 24: ...he flushing water hose regeneration water flows out under pressure 3 Shorten the overflow hose diameter 16 mm to the required length 4 Run the overflow hose to the drain with a downward slope 5 Make s...

Страница 25: ...lay see chapter 6 Use the or buttons to navigate through the program Press to go to the previous menu level With you confirm the selection and move to the next menu level 5 1 1 Initial start up and au...

Страница 26: ...the correct system connection 2 Select the drain connection used 3 Check whether the lines to the drain connection have been laid with a gradient 4 Place the water sensor flat on the floor 5 Fill sal...

Страница 27: ...er to chapter 6 6 8 Type in the value for the raw water hardness You can change the value at a later time refer to chapter 6 6 After the set value has been confirmed the automatic positioning of the c...

Страница 28: ...normal during start up 11 Start the ventilation program There is an automatic sequence of 11 program steps This is followed by a 5 step functional check The soft water sample must be determined for e...

Страница 29: ...soft water hardness a Observe the max sodium concentration refer to chapter 12 1 17 On the touch display of the controller type in the setpoint soft water hardness we recommend 3 6 dH Exception for Au...

Страница 30: ...test regeneration lasts approx 33 minutes The remaining time is displayed continuously Let the test regeneration run The start up program is finished Check that the water sensor is lying flat on the...

Страница 31: ...program cannot be started while a regeneration is running 5 2 Handing over the product to the owner user Explain to the owner user how the water softener works Use the manual to brief the owner user...

Страница 32: ...er supply if necessary 6 1 Touch display 6 1 1 Basic display The touch display is switched off by default It is activated by tapping on the touch display If you do not tap for 2 minutes the control un...

Страница 33: ...n Information This menu offers useful information on the water softener Manual regeneration In this menu you can manually start a regeneration refer to chapter 6 5 Settings In this menu you can adapt...

Страница 34: ...ting Slow rinse Backwash Washing out uppermost bar Current flow rate The current flow rate is displayed as a numerical value and in the form of a tachometer blue coloured circle segments If the nomina...

Страница 35: ...connection to the Gr nbeck Cloud is established 6 1 4 Operating elements Button Description Return to the basic display and Scroll through the menu level and mark a selection scroll to the menu items...

Страница 36: ...Technical service The technical service menu is reserved for Gr nbeck s technical service authorised service company and specialist installers trained by Gr nbeck and is protected by a code Manual reg...

Страница 37: ...nal illuminated LED ring Display Display in standby Deactivated Activated Audio signal behaviour in case of malfunctions Deactivated Activated Audio signal release from to Illuminated LED ring functio...

Страница 38: ...for 2 seconds to check for updates Reset factory settings Start Device info Software version hardware version serial number control unit maintenance interval d Water hardness Setting the water hardnes...

Страница 39: ...e Gr nbeck myProduct app and the softliQ control system is made in the following way Item Designation Item Designation 1 Gr nbeck product 2 Router 3 Gr nbeck Cloud 4 Mobile device The following steps...

Страница 40: ...an app You can register your product conveniently using the Gr nbeck myProduct app Call up Registration and Product registration in the device overview of the Gr nbeck myProduct app Enter your persona...

Страница 41: ...eway indication only Data is assigned by the router Primary DNS indication only Data is assigned by the router Secondary DNS indication only Data is assigned by the router Status indication only conne...

Страница 42: ...ter Connecting via Wi Fi You need an Ethernet patch cable that is not included in the scope of delivery 1 Unscrew both the screws at the side on the upper part of the housing for technical equipment 2...

Страница 43: ...ng a loop 7 Attach the upper part of the housing of the technical equipment The Ethernet patch cable is routed out of the housing with the connection hoses 8 Fasten the upper part of the housing of te...

Страница 44: ...on 1 Start the WPS function on your router by holding down the corresponding button for a few seconds 2 Select Start on the control unit at Auto Wi Fi connection The Wi Fi connection is established wi...

Страница 45: ...nter the serial number 2 Give your softliQ a device name Menu level Settings Cloud connection Gr nbeck Cloud user account connection 3 Tap Pair 4 Press and hold the button in the app for 2 seconds You...

Страница 46: ...cm above the sieve bottom 1 Open the brine tank lid The brine tank lid on the softliQ contains the sensor for the brine level display This sensor does not work with laser light so it is safe for the e...

Страница 47: ...ion of the water hardness in dH or in f The unit mol m mmol l can be converted from f Item Description Item Description 1 Test tube 2 Titration solution 6 6 1 Taking a water sample Open the water with...

Страница 48: ...s has been determined The number of drops corresponds to the degree of hardness in dH or f Example Test tube filled up to the dH mark 6 drops 6 dH Test tube filled up to the f mark 6 drops 6 f 6 6 3 D...

Страница 49: ...1 Choose Define time x 2 Enter the time of day for the 3 possible times 3 Confirm each with 6 8 Installer level code 005 The settings described here may only be made by Gr nbeck s technical service au...

Страница 50: ...Raw water hardness dH Total flow rate indication only Parallel operation peak value m h for xxxxx min Flow rate exchanger 1 indication only Exchanger 1 peak value m h for xxxxx min Flow rate exchanger...

Страница 51: ...eneration on each day of the week factory setting Mon Fri 7 00 am Save settings profile none factory setting yes Save all current parameter settings of the control unit in the Gr nbeck Cloud so that y...

Страница 52: ...nput is closed manually released and automatic regenerations after a power failure take priority A regeneration that has already been started is not cancelled Release of regeneration Start of a partia...

Страница 53: ...ures trouble free hygienic operation At least once a year the water softener must be serviced by Gr nbeck s technical service authorised service company or by specialist installers trained by Gr nbeck...

Страница 54: ...Check the control valve to the drain for leaks No water is allowed to drip out of the flushing water hose during operation The water softener is in operation when the blue symbol is displayed in info...

Страница 55: ...s in the brine tank must always be higher than the water level The water level is normally approx 1 cm above the sieve bottom 3 Evaluate the salt consumption subject to the water volume consumed 4 Che...

Страница 56: ...Maintenance work on the exchangers Subsequent work must be carried out per exchanger 10 Check the hose connections for leaks and damage 11 Check the soft water meter for pulse emission current flow d...

Страница 57: ...on log refer to chapter 13 7 5 Consumables Product Order no Regeneration salt tablets 25 kg acc to DIN EN 973 type A 127 001 Water test kit Total hardness 170 187 7 6 Spare parts For spare parts and c...

Страница 58: ...are listed below Control valve Gaskets set of discs injector and chlorine cell Item Designation Item Designation 1 Injector with circlip 2 Chlorine cell with circlip 3 Regeneration disc pair with flow...

Страница 59: ...data refer to chapter 1 7 handy 8 1 Display messages 1 Acknowledge the display signal with rectify 2 Watch the display 3 If the fault occurs again compare the display message with the following table...

Страница 60: ...chapter 6 3 Confirm with Rectify Water pressure too low Increase the flow pressure to min 2 0 bar Chlorine cell worn Brine filling orifice injector injector sieve or brine valve clogged Notify Gr nbec...

Страница 61: ...Gr nbeck s technical service authorised service company Nominal flow rate exceeded Only displayed if monitoring was activated by the specialist installer System is being operated with excessive flow...

Страница 62: ...ng backwash has tripped No flow was detected at the regeneration water meter Check that the shut off valves on the connection block are open Error during start up fill brine tank Time monitoring for f...

Страница 63: ...er hose or aerator Defective jet system Notify Gr nbeck s technical service authorised service company Water pressure at the withdrawal point too low Pressure loss too high Resin may be polluted by un...

Страница 64: ...Leave your product connected to electricity and water Should you wish to temporarily shut down your water supply due to a longer period of absence proceed as follows 1 Close the soft water shut off va...

Страница 65: ...3 Wait for a few seconds The pressure in the product and the pipe network is being relieved 4 Close the water withdrawal point 5 Disconnect the product from mains 6 Separate the product from the conn...

Страница 66: ...This means that this product or the electric and electronic components are not allowed to be disposed of in the household waste Find out about local regulations on the separate collection of electric...

Страница 67: ...C System depth mm 580 D Connection height of control valve soft water mm 480 E Connection height of control valve raw water mm 518 F Height of safety overflow of brine tank mm 540 G Height with open l...

Страница 68: ...8 2 x 20 2 x 14 2 x 36 2 x 1 4 2 x 3 6 Capacity per kg of regeneration salt mol kg 7 3 4 4 Regeneration time for a complete regeneration min 40 80 Regeneration 1x per day in case of reduction in capac...

Страница 69: ...you about the sodium content of your raw water Sample calculation Raw water hardness 28 dH 50 f 5 mmol l Sodium content in the raw water 10 5 mg l Admissible increase of the sodium content by softenin...

Страница 70: ...onnection acc to DIN EN 1717 yes no Floor drain available yes no Safety device yes no Regeneration water lifting system yes no Make Dosing yes no Active agent Operating values Water pressure bar Readi...

Страница 71: ...er checked for pulse output Regeneration water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve l...

Страница 72: ...er checked for pulse output Regeneration water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve l...

Страница 73: ...er checked for pulse output Regeneration water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve l...

Страница 74: ...er checked for pulse output Regeneration water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve l...

Страница 75: ...er checked for pulse output Regeneration water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve l...

Страница 76: ...er checked for pulse output Regeneration water meter checked for pulse output Cables checked for damage and firm seating Injector and injector sieve cleaned checked Chlorine cell checked Brine valve l...

Страница 77: ...The aforementioned system also complies with the following directives and provisions Directive on the Restriction of Hazardous Substances RoHS 2011 65 EU Electrical and Electronic Equipment Ordinance...

Страница 78: ...ection 53 54 Inspection maintenance intervals 54 M Maintenance 53 55 56 Malfunction 14 51 52 59 Menu structure 36 O Operation 64 P Power mode 13 R Raw water 28 69 Regeneration agent 9 Regeneration wat...

Страница 79: ......

Страница 80: ...Gr nbeck Wasseraufbereitung GmbH Josef Gr nbeck Str 1 89420 Hoechstaedt GERMANY For more Information go to www gruenbeck com 49 9074 41 0 49 9074 41 100 info gruenbeck com www gruenbeck com...

Отзывы: