Table D-5: Installation dimensions
1)
GENO-mat filter systems
20/10 25/13 30/14 40/17 40/18 50/19 60/20
A
Total
height
[mm]
1360 1620 1620 1900 1900 1870 2100
B Pressure cylinder
[mm]
210 260 340 370 420 550 620
E Connection height/
raw water piping
[mm]
1160 1420 1420 1710 1710 1680 1910
F Connection height/
pure water piping
[mm]
1210 1470 1470 1735 1735 1705 1935
H Distance to wall
[mm]
200
230
280
280
300
365
405
I
Foundation
depth
[mm]
400 450 500 500 550 600 650
K Foundation length
[mm]
705
755
860
860
900
1030
1110
1)
All indications are approximate.
Caution!
Dirt and corrosion particles might damage the system
(control valve). Flush the supply pipe prior to start-up.
2. Establish waste water connection as per DIN EN 1717. Shorten
the rinse water hose to the correct length and guide it to the drain.
Ensure there is a free outlet (min. 20mm) to the drain. Secure the
hose with suitable fittings to prevent the hose from moving about
(regeneration water is pressurised).
Caution!
Danger of damage and malfunctions due to a waste water
backflow. Therefore, do not bend the hose and do not lead it higher
than the system height.
3. Connect the mains plug to the socket (see 1.2).
4. Water the system (not the KF-Z)
In order to prevent the filter material from being washed out, it
must be watered for 24 hours.