Start-up
32 | 74
BA_
T
D
3-
BM
001e
n_
01
4_D
e
lta-
p.
docx
No.
Designation
No.
Designation
1
Bottle adapter
2
Withdrawal valve
Hardness determination
1.
Perform the 0 °dH (0 °f, 0 mmol/l) test. To do this, take water samples from the
water softener in operation:
a
Open one of the customer's withdrawal points downstream of the water
softener. Without this measure, you will receive a mixture of waters from the
exchanger* and exchanger** at the sample valves.
b
Take samples from each of the three bottle adapters on its sampling valve.
c
In the case of systems with a blending valve, take an additional water sample at
the client's withdrawal point downstream of the system.
d
Close the client's withdrawal point downstream of the water softener
2.
Measure the hardness of the samples with the water test kit "total hardness".
3.
Record your work in the
start-up log
and countersign it (refer to chapter 14).
Carrying out 1st maintenance
► Carry out maintenance according to the checklist for
1st maintenance
and record
the determined data.
» You have completed the start-up.
Содержание Delta-p
Страница 1: ...We understand water Softening Water softener Delta p Operation manual ...
Страница 57: ...Mounting instructions 57 74 BA_TD3 BM001en_014_Delta p docx ...
Страница 58: ...Mounting instructions 58 74 BA_TD3 BM001en_014_Delta p docx ...
Страница 59: ...Mounting instructions 59 74 BA_TD3 BM001en_014_Delta p docx ...
Страница 60: ...Mounting instructions 60 74 BA_TD3 BM001en_014_Delta p docx ...
Страница 62: ...Mounting instructions 62 74 BA_TD3 BM001en_014_Delta p docx ...
Страница 72: ......