Mobile reverse osmosis system
AVRO-flex 400
Order no.
095 752 946-inter Edited by: phar-mrie G:\BA-752946-INTER_095_AVRO-FLEX_400.DOCX
35
3.4 Error memory / water volumes Code 245
Display
Parameters
Comment
1.Er_x
...
9.Er_y
Error memory of the 9
most recent errors
1.Er_ = most recent error
9.Er_ = least recent error
▼
A.0372
Operating time [hours]
in workshop mode
Time during which the HP pump is operating in work-
shop mode.
b.0231
Run time filling mode
[days]
c.0097
d. 00
Run time HP pump
[hours]
Filling mode c = thousands … ones
d = ten thousands
E.0068
F. 00
No function
No function
No function
G.0103
H. 00
Permeate volume pro-
duced so far [m³]
G = thousands … ones
H = ten thousands
I.0085
L. 00
Concentrate volume
produced so far [m³]
I = thousands … ones
L = ten thousands
3.5 Diagnosis Code 653
In this code of the customer service programming level, it is possible to
request the states of the inputs and to switch the outputs separately.
Access requirement: System is switched off via ▼ button.
E.PA:
Motor protection switch of high-
pressure pump
Physical state of the input signals:
0 = no voltage applied
1 = 24 VDC voltage applied
E.Pb:
Switch for workshop mode
E.Pc:
Switch for filling mode
E.HP:
Pressure switch for minimum pres-
sure of high-pressure pump
E.PS:0
Pressure switch
System ON - Filling mode
E.CL:
Input always 1
Motor protection switch PS pump
A.St:0
Voltage-free fault signal contact
Physical state of the output signals:
0 = output switched off
1 = output switched on
Attention!
Make sure there is an inflow of wa-
ter when switching the pumps - risk of running
dry!
A.YE:0
Inlet solenoid valve
A.YS:0
Flushing solenoid valve
A.Yr:0
Reserved
A.HP:0
High-pressure pump
A.PS:0
No function
A.PF:0
Voltage-free signal contact