Mobile reverse osmosis system
AVRO-flex 400
Order no.
095 752 946-inter Edited by: phar-mrie G:\BA-752946-INTER_095_AVRO-FLEX_400.DOCX
31
Operating modes selector switch
Workshop mode
When the system is switched on (symbol ), permeate
is produced for 15 minutes at the same time every day.
Filling mode
When the system is switched on (symbol l ), it pro-
duces subject to the pressure switch for operational re-
lease.
Off
2.1 Reading the
operating status
Various operating parameters can be displayed within the Info level.
The Info level is accessed by pressing the ▲ button.
Button
Display
Parameters
00:00
Basic display, time
Pressing this button for the first time switches the system on, if
still necessary!
365
Remaining time of maintenance interval [d]
3000
Remaining time of AVRO maintenance interval [h]
P0200
Permeate flow [l/h]
c0200
Concentrate flow [l/h]
A 050
System recovery [%]
l.200
Actual current of AVRO treatment module [mA]
S00.00
Sum of permeate [m³] during filling mode for bill-
ing. Counter reading is deleted again in this dis-
play by the combination of buttons P and
▲
(> 5 sec).
2.2 How to set the
time
Requirement:
The basic display time is currently being indicated.
1. Press button P for > 2.5 seconds. Only the hours 00: will still be dis-
played
2. Press P button to change the hours (value is flashing, now set the
desired value with buttons ▼ or ▲ and save with the P button)
or
press▲ button to advance to the minutes :00
3. Press P button to change the minutes (value is flashing, now set the
desired value with buttons ▼ or ▲ and save with the P button)
4. Return to the basic display time by simultaneously pressing buttons
▼ and▲