SNAP,

CLICK,

Getting Started Guide

Содержание sateon ADVANCE

Страница 1: ...DONE SNAP CLICK Getting Started Guide ...

Страница 2: ...range of door elements such as locks and exit buttons See page 10 for connection details Advance Single Blade Controller The compact Single Blade controller is ideal when you only have a small space available The device supports either one Door Blade or one I O Blade and it can be powered via PoE or a separate external power supply For details see page 6 Sateon Server The hardware is based on a mo...

Страница 3: ...e can be used when you need to connect additional peripherals It enables the connection of up to 8 volt free relay outputs and 8 supervised inputs The Blade can be used in either Single Blade or Multi Blade controllers See page 12 for connection details Sateon Quick Start Application Installing and configuring a Sateon system is straightforward with the Quick Start application which will discover ...

Страница 4: ...age 4 Network Configuration IP ONLY NETWORK Controller 485 relay mode enabled RS485 RS485 ONLY NETWORK HYBRID IP AND RS485 NETWORK Controller 485 relay mode enabled RS485 IP IP IP IP Switch Switch Switch ...

Страница 5: ...nected I O devices Readers locks and other connected I O devices Single Blade Controller with Lithium Polymer Battery PoE switch injector Mains Power Mains Power Battery PSU Multi Blade Controller with PSU and Enclosure CAT5e or above 100m max Power Options ...

Страница 6: ...wer outages When selecting the most suitable power supply calculate The total power consumption of the controller itself its components and the Blade fitted This will include Controller quiescent power 3 0W max 250mA Battery charging power up to 2 0W max 167mA when battery depleted Door Blade if fitted 1 0W I O Blade if fitted 4 0W The total power requirements for all the locks readers etc that wi...

Страница 7: ...table 12V external power supply if used Connect the IP and or RS485 cable as required See page 18 for details If using PoE IP connection will apply power to the controller Snap the Blade into the controller Ensure the Blade is inserted before any power source is connected For Door Blade connections see page 8 For I O Blade connections see page 10 Install the lithium polymer back up battery if requ...

Страница 8: ... power consumption of the controller itself its components and fitted Blades This will include Controller quiescent power 3 6W max 300mA Battery charging power depends on the power supply used e g for 12V 5A PSU assume max 6 0W 0 5A Each door Blade fitted 1 0W Each I O Blade fitted 4 0W The total power requirements for all the locks readers etc that will be connected to all the Blades Power supply...

Страница 9: ...r is applied For Door Blade connections see page 8 For I O Blade connections see page 10 Run cabling to the enclosure from all the doors readers locks inputs and outputs that are to be connected The controller can be installed in a Grosvenor enclosure or a third party enclosure Attach the enclosure to the wall using the fixing points Install the controller in the enclosure Connect the physical tam...

Страница 10: ...A RS485 B Clock D1 Data D0 Valid Beeper Tamper 12 V 5 V GND RS485 A RS485 B Clock D1 Data D0 Valid Beeper Tamper HID Reader connections Sateon Reader connections Setting up a 2 Door Blade Door Reader 1 Door Reader 2 I O 1 I O 2 External power Page 10 Wiegand keypads can be supported using the same wiring Exit switch Door sensor 12 V Sounder GND REX GND Sensor Sounder Door Connections Contact Only ...

Страница 11: ...k requires power to release the lock The door would remain locked in the case of a power failure A Fail Safe lock requires power to lock the door The door would be unlocked in the case of a power failure External Lock Power Supply 12 24 V dc GND In 0V 12 24V IN Input Output Connections The inputs can be supervised and may optionally be used with line resistors for fault or tamper detection Input s...

Страница 12: ...controller or the Multi Blade controller to support extra peripherals Input switch 1K 1K GND In 1 Out NO Com Out NC 1 Normally Closed Contact Common Normally Open External power Supervised may optionally be used with line resistors for fault or tamper detection Input Connections Input switch GND In 1 Output Connections The output relays offer volt free contacts and may be used to connect to low vo...

Страница 13: ...t a network cable 3 Connect the power supply and press the power button 4 Once the Mini PC has started up log on to it as follows Username Administrator Password sateon 0 To access Sateon from another workstation From any other computer on the network open Internet Explorer and enter https hostname SATEON Where hostname is the name of your SATEON Mini PC The hostname can be found on the label on t...

Страница 14: ... GB RAM and a 64 GB hard drive Larger systems may need higher specifications The operating system must be Windows Server 2012 R2 Server 2016 R2 Windows 8 1 or Windows 10 Professional or Enterprise Make sure all Service Packs and updates are installed The Express option will set up everything needed to run Sateon on a single computer including SQL Server 2016 You may need to restart the computer pa...

Страница 15: ...cence and the System Administration Licence Info page is displayed as below A licence is required before any other pages can be viewed This is a two step process Load the new licence to access all licensed Sateon options Validate the licence within 30 days by calling Grosvenor Technical Support Your licence file is specific to your installation It will be provided on a USB stick under the licence ...

Страница 16: ...ence loads succesfully the following dialog appears Click Finish At this point the licence is loaded but not validated It will need to be validated within 30 days for Sateon to continue to operate 3 Select Upload Licence A file selection dialog appears Navigate to the appropriate file with the gtl file extension and click Open then Save 2 1 2 3 ...

Страница 17: ... the status will appear as ADDED Not Validated Click Validate Licence at the bottom of the page 4 Contact Grosvenor Support You will need your Licence ID and the 16 digit Validation Code from this page Technical Support will give you a 16 digit code number enter this in the lower box Click Validate You will be logged out 5 4 6 5 6 ...

Страница 18: ...as quickly as possible Run Quick Start From the Sateon server select the Quick Start desktop icon Quick Start can also be run from the supplied USB flash drive In the Sateon Server box enter the name of the computer that Sateon is installed on Click Login The Sateon Login screen appears Log in to the Sateon system using an admin username and password ...

Страница 19: ...k Start App the settings dialog is displayed Choose the Reader Token type used on your site and click Save Close Set the communication direction for the controller if you are unsure the default selection is Outbound To change the default settings later select the settings icon from the main screen Discovering Controllers ...

Страница 20: ...iguration Offline The controller is on the network but is not communicating with Sateon Unlicensed The controller hardware doesn t match the licence Contact Grosvenor Technical Support Each NEW controller is identified by its unique serial number You can check this against the label on the controller itself Total number of controllers that have been found on the network and the quantity in each st...

Страница 21: ...IP networks select IP only The addressing options appear 2 Choose Use DHCP if IP addresses are to be dynamically assigned or choose Use Static IP Address to assign a static IP address If you choose Use Static IP Address complete the IP Address Subnet and Gateway If necessary check the IP settings with the network administrator Click OK to save the settings Sateon can now connect to the controller ...

Страница 22: ...rollers in a RS485 chain Different addressing options appear For Relay controllers define the IP settings and set the baud rate for the RS485 line defaults to 19200 One controller must be configured as a Relay controller it acts as a line header and requires an IP connection as well as a RS485 line All other linked controllers must be configured as 485 only 2 3 For 485 Only controllers choose the ...

Страница 23: ...p door and readers Setting up inputs and outputs Configuring Access Setting up reader groups Setting up time patterns schedules Setting up a new access group set Granting Access to a person Personnel Module Guide Setting up Personnel Setting up a new personnel record Managing a person s access Managing a person s tokens Once the controllers are configured the set up of the system can be completed ...

Страница 24: ...hnology Ltd 2nd Floor Endeavour House Coopers End Road Stansted Essex CM24 1SJ United Kingdom Tel 44 0 1279 838000 Email ac support grosvenortechnology com Web www grosvenortechnology com Part No TD GSG 1 Version 4 ...