Application 

Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters  
Operation with low-pressure storage heaters 
(displacement water heaters) is not possible.

Specifications 

Max. flow

      8.3 L/min or 2.2 gpm/60 psi

Flow pressure   
- min.                                       

7.25 psi

- recommended                         

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure 
  reducing valve

Max. operating pressure                      

145 psi

Test pressure                                

232 psi

Temperature    
- max. (hot water inlet)                      

176 

°

F

Scalding protection possible by fitting a handle 
rotation stop (order no. 46 308).

Water connection                                    

hot - LH

         cold - RH

Non reversible cartridge

Note
Major pressure differences between hot and cold 
water supply should be avoided.

Installation

Flush pipes thoroughly.

Mount faucet on basin
See dimensional drawing fold-out page I.

For installation you require only a 13mm (1/2’’) socket 
wrench, see fold-out page III, fig. [1].

Connect faucet
For this purpose the supply tubes must be connected 
to the angle stops (or other supply points), see fig. [1].

The hot water supply should be connected on the left, 
the cold water supply on the right side.

Avoid cross connection. The cartridge is not 
reversible.

Fit pop-up drain (28 957), see fold-out page II, ensure 
that flange of pop-up drain is sealed.

Open angle stops and check faucet for correct 
function,
 see fig. [2].
Lift lever 

= open (water flow)

Press lever down

= closed (off)

Move lever to right 

= cold water 

Move lever to left 

= hot water

Check connections for leakage.

Flow rate limiter

This mixer is fitted with a flow rate limiter, permitting an 
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory 
before despatch. 
The use of flow rate limiters in combination with 
hydraulic instantaneous water heaters is not 
recommended.
For commissioning see “replacing the cartridge”    
point 1 to 3, fig. [3] and [4].

Maintenance

Inspect and clean all parts, replace as necessary and 
grease with special grease (order no. 18 012).

I. Replacing the cartridge, see fig. [3].
1. Remove cover cap (A).
2. Remove screw (B) and pull off lever (C).
3. Remove cap (D).
4. Remove screws (F) and detach complete 

cartridge (G).

5. Change either complete cartridge (G) or seals (G1).

Assemble in reserve order.

Make sure that the cartridge seals (G1) engage in the 
grooves on the housing. Fit screws (F) and tighten 
evenly and alternately.

II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (13 955).
Assemble in reverse order.

Replacement parts, see fold-out page II ( * = special 
accessories).

Care

Instructions for care of this single lever faucet will be 
found in the Limited Warranty supplement.

954852.book : i95485us.fm  Seite 1  Donnerstag, September 20, 2001  8:49 AM

Содержание Chiara 33148

Страница 1: ...página 3 English Français Español page 1 page 2 95 485 231 ÄM 90 775 09 01 Chiara 33 148 954852 book t95485 fm Seite 1 Donnerstag September 20 2001 8 49 AM ...

Страница 2: ...tion à l utilisateur de la robinetterie Sirvanse pasar ese instrucción al utilizador de la grifería Please pass these instructions on to the end user of the fitting 954852 book t95485 fm Seite 2 Donnerstag September 20 2001 8 49 AM ...

Страница 3: ...II 954852 book t95485 fm Seite 3 Donnerstag September 20 2001 8 49 AM ...

Страница 4: ...ure that flange of pop up drain is sealed Open angle stops and check faucet for correct function see fig 2 Lift lever open water flow Press lever down closed off Move lever to right cold water Move lever to left hot water Check connections for leakage Flow rate limiter This mixer is fitted with a flow rate limiter permitting an infinitely individual variable reduction in the flow rate The highest ...

Страница 5: ...ir volet II s assurer que le joint de clapet est étanche Ouvrir les robinets d équerre et vérifier que le mitigeur fonctionne correctement voir fig 2 Soulever le levier ouvert écoulement d eau Appuyer sur le levier fermé Levier tourné vers la droite eau froide Levier tourné vers la gauche eau chaude Vérifier l étanchéité des raccordements Limiteur de débit Cette robinetterie est équipée d un limit...

Страница 6: ...brir las llaves de escuadra y comprobar el cor recto funcionamiento del mezclador ver la fig 2 Levantar palanca abrir sale el agua Bajar palanca cerrar Girar palanca a la derecha agua fría Girar palanca a la izquierda agua caliente Revisar las coneciones para comprobar la ausencia de escapes Limitador de caudal Este monomando está equipado con una limitación de caudal Gracias a ello es posible una...

Страница 7: ...III 13mm 1 16mm 1 2 5 8 2 3 D F G G1 A B C 4 2 5mm 2 5mm 954852 book kr95485 fm Seite 4 Donnerstag September 20 2001 8 49 AM ...

Страница 8: ...954852 book notizen fm Seite 5 Donnerstag September 20 2001 8 49 AM ...

Страница 9: ...954852 book notizen1 fm Seite 6 Donnerstag September 20 2001 8 49 AM ...

Страница 10: ...954852 book adresus fm Seite 7 Donnerstag September 20 2001 8 49 AM ...

Отзывы: