background image

OM-CC-E

7

Drain Tank

Tabletop Model

CC10-E ELECTRICAL SUPPLY CONNECTION

(All wires copper only.

Reference: National Electrical Code)

Voltage

Phase

Wire Size

Insulation

208

1

6AWG (4.1mm)

75

o

C

208

1

8AWG (3.3mm)

90

o

C

208

3

8AWG (3.3mm)

75

o

C

240

1

8AWG (3.3mm)

75

o

C

240

3

8AWG (3.3mm)

75

o

C

f.

Branch Circuit Protection

Groen strongly recommends that each
Convection Combo™ have its own branch
circuit protection.  A double stacked unit should
have separate protection for the upper and
lower steamer-ovens.

CURRENT DEMAND

Voltage

Current

Power

1 Phase

3 Ph., per Line

208

44.7 A

27.5 A

9.3 KW

240

38.8 A

24.1 A

9.3 KW

Each current-carrying conductor must have
overcurrent protection.  Refer to the label on
the back of the unit for proper wire size and
type.  Watertight connections are required.

3. Water Supply Connection

A check valve (back siphonage device) must be
installed in the incoming 

cold

 water line in keeping

with local plumbing codes.  Water line pressure
should be between 30 and 60 PSI (210 and 410
kPa).  A pressure regulator is required above 60
PSI (410 kPa).

A ¾ inch (19 mm) NH (garden hose type)
connector is required to connect the water supply
to the water inlet valve.  The water feed line
diameter may not be less that ½ inch (13 mm). 
Use a washer (or if necessary, two washers) in the
hose connection.  Do not allow the connection to
have any leak, no matter how small.

If your CC10-E is equipped with the optional split
water supply, the supply for 

each

 steam generator

must be able to fill the generator with 1½ gallons
(5.7 liters) or water in 1½ minutes.  The make-up
water rate is 0.06 gallons per minute (0.2 liters per
minute).  Condensate spray water rate is 0.34
gallons per minute (1.3 liters per minute) at 30 PSI
(210 kPa).

4. Drain Connection

a.

CC10-E Without Drain Tank

 

(tabletop model)

A 1½ inch (4 cm) hose may be attached to the
provided drain elbow with a clamp.  Do 

not

 use

plastic pipe. The drain must withstand boiling
water.

WARNING

:

DO NOT CONNECT THE DRAIN DIRECTLY TO A
BUILDING DRAIN.

There must be a free air gap between the end
of the hose and the building drain.  The free air
gap should be as close as possible to the unit’s
drain.  There must also be no other elbows or
other restrictions between the unit drain and the
two inch free air gap.

CAUTION

DO NOT USE PLASTIC PIPE.  DRAIN MUST BE
RATED FOR BOILING WATER.

WARNING

BLOCKING THE DRAIN IS HAZARDOUS.

Install the drain line with a constant downward
pitch.  

IMPORTANT:  Do not allow any water traps in the
line.  A trap can cause pressure to build up inside
the cavity during steaming, which will make the
door gasket leak. 

NOTE:

 Improper drain connection will void the warranty.

b.

CC10-E With Drain Tank

A 1½ inch (4 cm) ID hose may be attached to
the supplied drain elbow with a clamp.  The
hose may be connected directly to a building
drain since the drain tank has an air vent, which
eliminates the need for a free air gap at the
building drain. Do not block the air vent in any
way.  Do not attach anything to the vent tube or
reduce its size.

Do NOT use plastic pipe in the drain line,
because the drain must withstand boiling water.

Содержание CC20-EF

Страница 1: ...ECTION COMBO Combination Steamer Oven THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL FOR YOUR SAFETY DO NOT STORE O...

Страница 2: ...THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLO...

Страница 3: ...TROUBLESHOOTING 25 SERVICE LOG 30 WARRANTY PROTECTION 31 References UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Min...

Страница 4: ...the cabinet at a thickness of 1 to 2 inches 4 to 5 cm A removable drip tray is located beneath the door Door hinges are reversible so that doors may open from the left or right side Operator controls...

Страница 5: ...your water The water going to the steam generator should have between 30 and 40 parts per million ppm total dissolved solids TDS and should have a pH acidity rating of 7 0 to 9 0 Please follow these s...

Страница 6: ...ove the two screws at the bottom of the panel Slide the panel toward the front of the unit lift it and set it aside b Supply Voltage The CC10 E must operate at the rated nameplate voltage plus or minu...

Страница 7: ...r each steam generator must be able to fill the generator with 1 gallons 5 7 liters or water in 1 minutes The make up water rate is 0 06 gallons per minute 0 2 liters per minute Condensate spray water...

Страница 8: ...OM CC E 8 Proper Drain Line Connections...

Страница 9: ...ground wire must be at least 8 AWG 3 3 mm for a 100 amp circuit breaker or 10 AWG 2 6 mm for a 40 to 60 amp breaker d Supply Wire The type of wire needed is determined by finding the operating voltage...

Страница 10: ...THE DRAIN IS HAZARDOUS IMPORTANT Do not allow any water traps in the line A trap can cause pressure to build up inside the cavity during steaming which will make the door gasket leak NOTE Improper dra...

Страница 11: ...62 13 14000 4267 14 15000 4572 15 5 For CC20 E only Check Fan Rotation IMPORTANT As seen from inside the oven cavity the fan should be turning in a counterclockwise direction If the fan is running bac...

Страница 12: ...ature is attained the WAIT light will go off and the READY light will come on NOTE The timer does not control the oven in either the Combo or Oven Modes 9 To Test Oven Mode Operation turn on the power...

Страница 13: ...display of 01 30 On some older units numbers higher than 59 will not be accepted in these cases convert the time to hours and minutes 90 minutes would be entered 1 3 0 b Time touch pads used to enter...

Страница 14: ...MP Section a The Temperature Display Window shows the selected temperature in either Oven or Combo Mode It is blank in the Steamer Mode or when the optional Hold Mode is operational b Turning the Temp...

Страница 15: ...was recently used in Oven or Combo Mode the HOT light may come on indicating that the cooking chamber is too hot for use as a steamer The unit can be cooled quickly to the steaming temperature range b...

Страница 16: ...pressing CLEAR twice A new cooking time may then be set by using the number keys 2 Oven Mode a To use the Convection Combo as a convection oven first switch on the electric power by pushing the ON to...

Страница 17: ...oking take the pans out of the oven using hot pads or oven mitts to protect your hands from the hot pans The unit will continue heating to keep the chamber at the set temperature until the temperature...

Страница 18: ...splay and enter the time again The timer does not control the unit in Combo Mode h Load the food into the pan or pans in a uniform layer WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM ANY STEAM COMING...

Страница 19: ...e timer will now count UP The COOK temperature display will be blank and the temperature of the unit will slowly drop to the HOLD temperature setting NOTE Food will continue to be cooked by the excess...

Страница 20: ...n operates with the door open WARNING DO NOT PUT HANDS OR OTHER OBJECTS INTO THE COOKING CHAMBER DURING THE FAST COOL OPERATION THE ROTATING FAN CAN BE HAZARDOUS b To stop the Fast Cool operation pres...

Страница 21: ...olution c Stainless steel surfaces may be polished with a recognized stainless steel cleaner such as Zepper PRECAUTIONS WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE UNIT KEEP...

Страница 22: ...e steam generator only if you see grease deposits h If there are grease deposits in the generator add to cup 60 to 125 ml of full strength degreaser to the generator or lightly coat the generator with...

Страница 23: ...door The timer will display CL 26 and count down automatically to CL 00 k Press the ON switch to turn off the unit Let the unit cool WARNING UNIT MAY BE HOT DO NOT TOUCH HOT SURFACES l Remove the righ...

Страница 24: ...and turn the latch pin turn clockwise Re tighten the lock nut b After adjustment run the unit to test for further steam leaks c If there is still leakage repeat the adjustment d Continue adjusting the...

Страница 25: ...rate in Oven Mode only Call your Groen Service Agency 7 Out of Calibration Units Before 3 97 Only The unit will operate in all modes Call your Groen Service Agency 7A Time Between Fills Units After 3...

Страница 26: ...OM CC E 26 CC10 E Heater Schematic CC10 E Control Schematic Diagrams Schematics...

Страница 27: ...OM CC E 27 CC20 E Control Schematic 480 Volts CC20 E Control Schematic 208 240 Volts Diagrams Schematics Continued...

Страница 28: ...OM CC E 28 CC20 E Heater Schematic 208 240 Volts CC20 E Heater Schematic 480 Volts Diagrams Schematics Continued...

Страница 29: ...OM CC E 29 CC20 E Heater Schematic 208 240 Volts Units That Meet Canadian Standards Association Requirements Diagrams Schematics Continued...

Страница 30: ...OM CC E 30 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Страница 31: ...tal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boile...

Страница 32: ...1055 Mendell Davis Drive OM CC E Revised 7 00 Jackson MS 39212 Part Number 121015 Rev A Telephone 601 372 3903 Fax 601 373 9587...