background image

OM-CC-E

31

LIMITED WARRANTY TO
COMMERCIAL PURCHASERS*

(Continental U.S., Hawaii and Canadian Sales Only)

Groen Foodservice Equipment (“Groen Equipment”) has been skillfully manufactured, carefully inspected, and
packaged to meet rigid standards of excellence.  Groen warrants its Equipment to be free from defects in material
and workmanship for (12) twelve months with the following conditions an subject to the following limitations.

I.

This parts and labor warranty is limited to Groen Equipment sold to the original commercial
purchaser/users (but not original equipment manufacturers {O.E.M.}), at its original place of installation in
the continental United States, Hawaii and Canada.

II.

Damage during shipment is to be reported to the carrier, is not covered under this warranty, and is the sole
responsibility of the purchaser/user.

III.

Groen,, or an authorized service representative, will repair or replace, at Groen’s sole election, any Groen
equipment, including but not limited to, draw-off valves, safety valves, gas and electric components, found
to be defective during the warranty period.  As to warranty service in the territory described above, Groen
will absorb labor and portal to portal transportation costs (time and mileage) for the first twelve (12)
months from date of installation or fifteen (15) months from date of shipment from Groen.

IV.

This warranty does not cover boiler maintenance, calibration, periodic adjustments as specified in
operating instructions or manuals, and consumable parts such as scraper blades, gaskets, packing, etc.,
or labor costs incurred for removal of adjacent equipment or objects to gain access to Groen Equipment. 
This warranty does not cover defects caused by improper installation, abuse, careless operation, or
improper maintenance of equipment.  This warranty does not cover damage caused by poor water quality
or improper boiler maintenance.

V.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED.  THE REMEDIES
DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL GROEN BE LIABLE FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE
OF THIS WARRANTY.

VI.

Groen Equipment is for commercial use only.  If sold as a component of another (O.E.M.) Manufacturer’s
equipment, or if used as a consumer product, such Equipment is sold AS IS and without any warranty.

*

(Covers all Foodservice Equipment Ordered after October 1, 1995)

Содержание CC20-EF

Страница 1: ...ECTION COMBO Combination Steamer Oven THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL FOR YOUR SAFETY DO NOT STORE O...

Страница 2: ...THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLO...

Страница 3: ...TROUBLESHOOTING 25 SERVICE LOG 30 WARRANTY PROTECTION 31 References UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Min...

Страница 4: ...the cabinet at a thickness of 1 to 2 inches 4 to 5 cm A removable drip tray is located beneath the door Door hinges are reversible so that doors may open from the left or right side Operator controls...

Страница 5: ...your water The water going to the steam generator should have between 30 and 40 parts per million ppm total dissolved solids TDS and should have a pH acidity rating of 7 0 to 9 0 Please follow these s...

Страница 6: ...ove the two screws at the bottom of the panel Slide the panel toward the front of the unit lift it and set it aside b Supply Voltage The CC10 E must operate at the rated nameplate voltage plus or minu...

Страница 7: ...r each steam generator must be able to fill the generator with 1 gallons 5 7 liters or water in 1 minutes The make up water rate is 0 06 gallons per minute 0 2 liters per minute Condensate spray water...

Страница 8: ...OM CC E 8 Proper Drain Line Connections...

Страница 9: ...ground wire must be at least 8 AWG 3 3 mm for a 100 amp circuit breaker or 10 AWG 2 6 mm for a 40 to 60 amp breaker d Supply Wire The type of wire needed is determined by finding the operating voltage...

Страница 10: ...THE DRAIN IS HAZARDOUS IMPORTANT Do not allow any water traps in the line A trap can cause pressure to build up inside the cavity during steaming which will make the door gasket leak NOTE Improper dra...

Страница 11: ...62 13 14000 4267 14 15000 4572 15 5 For CC20 E only Check Fan Rotation IMPORTANT As seen from inside the oven cavity the fan should be turning in a counterclockwise direction If the fan is running bac...

Страница 12: ...ature is attained the WAIT light will go off and the READY light will come on NOTE The timer does not control the oven in either the Combo or Oven Modes 9 To Test Oven Mode Operation turn on the power...

Страница 13: ...display of 01 30 On some older units numbers higher than 59 will not be accepted in these cases convert the time to hours and minutes 90 minutes would be entered 1 3 0 b Time touch pads used to enter...

Страница 14: ...MP Section a The Temperature Display Window shows the selected temperature in either Oven or Combo Mode It is blank in the Steamer Mode or when the optional Hold Mode is operational b Turning the Temp...

Страница 15: ...was recently used in Oven or Combo Mode the HOT light may come on indicating that the cooking chamber is too hot for use as a steamer The unit can be cooled quickly to the steaming temperature range b...

Страница 16: ...pressing CLEAR twice A new cooking time may then be set by using the number keys 2 Oven Mode a To use the Convection Combo as a convection oven first switch on the electric power by pushing the ON to...

Страница 17: ...oking take the pans out of the oven using hot pads or oven mitts to protect your hands from the hot pans The unit will continue heating to keep the chamber at the set temperature until the temperature...

Страница 18: ...splay and enter the time again The timer does not control the unit in Combo Mode h Load the food into the pan or pans in a uniform layer WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM ANY STEAM COMING...

Страница 19: ...e timer will now count UP The COOK temperature display will be blank and the temperature of the unit will slowly drop to the HOLD temperature setting NOTE Food will continue to be cooked by the excess...

Страница 20: ...n operates with the door open WARNING DO NOT PUT HANDS OR OTHER OBJECTS INTO THE COOKING CHAMBER DURING THE FAST COOL OPERATION THE ROTATING FAN CAN BE HAZARDOUS b To stop the Fast Cool operation pres...

Страница 21: ...olution c Stainless steel surfaces may be polished with a recognized stainless steel cleaner such as Zepper PRECAUTIONS WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE UNIT KEEP...

Страница 22: ...e steam generator only if you see grease deposits h If there are grease deposits in the generator add to cup 60 to 125 ml of full strength degreaser to the generator or lightly coat the generator with...

Страница 23: ...door The timer will display CL 26 and count down automatically to CL 00 k Press the ON switch to turn off the unit Let the unit cool WARNING UNIT MAY BE HOT DO NOT TOUCH HOT SURFACES l Remove the righ...

Страница 24: ...and turn the latch pin turn clockwise Re tighten the lock nut b After adjustment run the unit to test for further steam leaks c If there is still leakage repeat the adjustment d Continue adjusting the...

Страница 25: ...rate in Oven Mode only Call your Groen Service Agency 7 Out of Calibration Units Before 3 97 Only The unit will operate in all modes Call your Groen Service Agency 7A Time Between Fills Units After 3...

Страница 26: ...OM CC E 26 CC10 E Heater Schematic CC10 E Control Schematic Diagrams Schematics...

Страница 27: ...OM CC E 27 CC20 E Control Schematic 480 Volts CC20 E Control Schematic 208 240 Volts Diagrams Schematics Continued...

Страница 28: ...OM CC E 28 CC20 E Heater Schematic 208 240 Volts CC20 E Heater Schematic 480 Volts Diagrams Schematics Continued...

Страница 29: ...OM CC E 29 CC20 E Heater Schematic 208 240 Volts Units That Meet Canadian Standards Association Requirements Diagrams Schematics Continued...

Страница 30: ...OM CC E 30 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Страница 31: ...tal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boile...

Страница 32: ...1055 Mendell Davis Drive OM CC E Revised 7 00 Jackson MS 39212 Part Number 121015 Rev A Telephone 601 372 3903 Fax 601 373 9587...

Отзывы: