Initial Start-Up

WARNING

ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING
PROCEDURES.

After the Convection Combo™ has been installed,
test it to ensure that it is operating correctly.

1.

Remove all literature and packing materials from
the interior and exterior of the unit.

2.

Check that the cold water supply line is open and
that none of the fittings are leaking.

3.

Turn on electrical service to the unit.

4.

High Altitude Operation.

  At altitudes above

5,000 feet (1524m), the unit will not operate in
the Steamer or Combo Modes unless the altitude
is set. You can program the altitude as follows:

a.

If the unit is on, turn it off by pressing the 

ON

touch pad.

b.

Press and hold the 

STEAM

 touch pad while

turning the unit on by pressing the 

ON

 touch

pad.  The Timer Display will show the letters
AL and a number representing the altitude in
thousands of feet.  If the altitude has not
been set for your unit, the display will be 0.

c.

Enter an altitude value between 0 and 15,
using the numbered touch pads.  For
example, if the unit will be operating at 7,000
feet, enter 7.

d.

Press the 

START

 touch pad.

Altitude Metric Conversion

Altitude

Setting

Feet

Meters

5000

1524

5

6000

1830

6

7000

2133

7

8000

2438

8

9000

2745

9

10000

3048

10

11000

3353

11

12000

3658

12

13000

3962

13

14000

4267

14

15000

4572

15

5.

For CC20-E only:

  

Check Fan

Rotation — IMPORTANT!

   As

seen from inside the oven cavity,
the fan should be turning in a
counterclockwise direction.  If the
fan is running backwards
(clockwise), have a qualified
electrician turn off the main power and switch
any two incoming power leads on the distribution
block. An incorrectly turning fan will eventually
shut the oven down.

6.

Select Farenheit or
Celsius
Temperatures.  

The

Convection Combo™
is delivered with the
Farenheit scale as
default.  To change
the current
temperature scale,
holding the 5 key in,
press ON. The Timer
Display will either
show dEG°F or
dEG°C.  Press the 5
key again to change
from one to the other. Press START to accept
the change.

7.

To Test Steamer Mode Operation

, turn on the

unit.  (For details of operating procedure, see the
Operation section of this manual.)  Clear time
from the time display.  Press the 

STEAM

 touch

pad.  (If the 

HOT

 light is on, see the Fast Cool

instructions in the Operation section.)  

The 

WAIT

 light will stay on while the steam

generator fills with and heats the water.  The

WAIT

 light should turn off within three minutes,

and the 

READY

 light should come on.  This

indicates that the water is at its standby
temperature.  The timer only controls operations
in the Steamer Mode.  Enter a time and press

START

.  (“Time” is set in minutes and hours

only.  Seconds are not displayed).

Examples:

2 minutes = 00:02 
(Just press 2).
1 hour and 30 minutes = 01:30
(Press 1, 3, and 0, or press 9,0
the timer will change to 1:30)

Содержание CC20-EF

Страница 1: ...ECTION COMBO Combination Steamer Oven THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL FOR YOUR SAFETY DO NOT STORE O...

Страница 2: ...THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLO...

Страница 3: ...TROUBLESHOOTING 25 SERVICE LOG 30 WARRANTY PROTECTION 31 References UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Min...

Страница 4: ...the cabinet at a thickness of 1 to 2 inches 4 to 5 cm A removable drip tray is located beneath the door Door hinges are reversible so that doors may open from the left or right side Operator controls...

Страница 5: ...your water The water going to the steam generator should have between 30 and 40 parts per million ppm total dissolved solids TDS and should have a pH acidity rating of 7 0 to 9 0 Please follow these s...

Страница 6: ...ove the two screws at the bottom of the panel Slide the panel toward the front of the unit lift it and set it aside b Supply Voltage The CC10 E must operate at the rated nameplate voltage plus or minu...

Страница 7: ...r each steam generator must be able to fill the generator with 1 gallons 5 7 liters or water in 1 minutes The make up water rate is 0 06 gallons per minute 0 2 liters per minute Condensate spray water...

Страница 8: ...OM CC E 8 Proper Drain Line Connections...

Страница 9: ...ground wire must be at least 8 AWG 3 3 mm for a 100 amp circuit breaker or 10 AWG 2 6 mm for a 40 to 60 amp breaker d Supply Wire The type of wire needed is determined by finding the operating voltage...

Страница 10: ...THE DRAIN IS HAZARDOUS IMPORTANT Do not allow any water traps in the line A trap can cause pressure to build up inside the cavity during steaming which will make the door gasket leak NOTE Improper dra...

Страница 11: ...62 13 14000 4267 14 15000 4572 15 5 For CC20 E only Check Fan Rotation IMPORTANT As seen from inside the oven cavity the fan should be turning in a counterclockwise direction If the fan is running bac...

Страница 12: ...ature is attained the WAIT light will go off and the READY light will come on NOTE The timer does not control the oven in either the Combo or Oven Modes 9 To Test Oven Mode Operation turn on the power...

Страница 13: ...display of 01 30 On some older units numbers higher than 59 will not be accepted in these cases convert the time to hours and minutes 90 minutes would be entered 1 3 0 b Time touch pads used to enter...

Страница 14: ...MP Section a The Temperature Display Window shows the selected temperature in either Oven or Combo Mode It is blank in the Steamer Mode or when the optional Hold Mode is operational b Turning the Temp...

Страница 15: ...was recently used in Oven or Combo Mode the HOT light may come on indicating that the cooking chamber is too hot for use as a steamer The unit can be cooled quickly to the steaming temperature range b...

Страница 16: ...pressing CLEAR twice A new cooking time may then be set by using the number keys 2 Oven Mode a To use the Convection Combo as a convection oven first switch on the electric power by pushing the ON to...

Страница 17: ...oking take the pans out of the oven using hot pads or oven mitts to protect your hands from the hot pans The unit will continue heating to keep the chamber at the set temperature until the temperature...

Страница 18: ...splay and enter the time again The timer does not control the unit in Combo Mode h Load the food into the pan or pans in a uniform layer WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM ANY STEAM COMING...

Страница 19: ...e timer will now count UP The COOK temperature display will be blank and the temperature of the unit will slowly drop to the HOLD temperature setting NOTE Food will continue to be cooked by the excess...

Страница 20: ...n operates with the door open WARNING DO NOT PUT HANDS OR OTHER OBJECTS INTO THE COOKING CHAMBER DURING THE FAST COOL OPERATION THE ROTATING FAN CAN BE HAZARDOUS b To stop the Fast Cool operation pres...

Страница 21: ...olution c Stainless steel surfaces may be polished with a recognized stainless steel cleaner such as Zepper PRECAUTIONS WARNING DISCONNECT THE POWER SUPPLY BEFORE CLEANING THE OUTSIDE OF THE UNIT KEEP...

Страница 22: ...e steam generator only if you see grease deposits h If there are grease deposits in the generator add to cup 60 to 125 ml of full strength degreaser to the generator or lightly coat the generator with...

Страница 23: ...door The timer will display CL 26 and count down automatically to CL 00 k Press the ON switch to turn off the unit Let the unit cool WARNING UNIT MAY BE HOT DO NOT TOUCH HOT SURFACES l Remove the righ...

Страница 24: ...and turn the latch pin turn clockwise Re tighten the lock nut b After adjustment run the unit to test for further steam leaks c If there is still leakage repeat the adjustment d Continue adjusting the...

Страница 25: ...rate in Oven Mode only Call your Groen Service Agency 7 Out of Calibration Units Before 3 97 Only The unit will operate in all modes Call your Groen Service Agency 7A Time Between Fills Units After 3...

Страница 26: ...OM CC E 26 CC10 E Heater Schematic CC10 E Control Schematic Diagrams Schematics...

Страница 27: ...OM CC E 27 CC20 E Control Schematic 480 Volts CC20 E Control Schematic 208 240 Volts Diagrams Schematics Continued...

Страница 28: ...OM CC E 28 CC20 E Heater Schematic 208 240 Volts CC20 E Heater Schematic 480 Volts Diagrams Schematics Continued...

Страница 29: ...OM CC E 29 CC20 E Heater Schematic 208 240 Volts Units That Meet Canadian Standards Association Requirements Diagrams Schematics Continued...

Страница 30: ...OM CC E 30 Service Log Model No Serial No Date Purchased Purchase Order No Purchased From Location Date Installed For Service Call Date Maintenance Performed Performed by...

Страница 31: ...tal to portal transportation costs time and mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boile...

Страница 32: ...1055 Mendell Davis Drive OM CC E Revised 7 00 Jackson MS 39212 Part Number 121015 Rev A Telephone 601 372 3903 Fax 601 373 9587...

Отзывы: