8
OM-BPM/BPP-G
1. To Tilt Pan Body
a
.
Manual Tilt Model
- Turn the tilting
handwheel clockwise to tilt the pan body, or
counterclockwise to return the pan body to
horizontal. 23 complete turns of the hand-
wheel will tilt the body 90 degrees to vertical.
b. Power Tilt Model -
(1) Press the power tilt switch marked “up” to
raise the pan or “down” to lower the pan.
(2) The spring loaded switch will return to the
OFF (middle) position when you release it.
(3) If the power tilt mechanism stops working
(see the Troubleshooting section) and you
must raise or lower the pan body without
delay, you can tilt the body by hand. Remove
the small plug on top of the control box and fit
the provided tool into the hole. Turn the tool
clockwise to lower it. It may take several
minutes to move the pan to the desired
position, but the operation can be speeded up
by substituting a reversible drill with a inc h
hexagonal driver bit in place of the tool.
CAUTION
REPLACE THE HOLE PLUG BEFORE CLEANING
OTHERWISE WATER COULD ENTER THE
ELECTRICAL CONTROL BOX AND DAMAGE
THE PARTS.
2.
For Standard Models with Electronic Ignition
(BPM, BPP-30G and 40G)
a. To Start Pan (See Panel Overlay)
(1) Set the Power Switch to “OFF.”
(2) Set the thermostat to “OFF.”
(3) Open the main supply gas valve (handle
parallel to the gas pipe).
Gas Valve “On” Gas Valve “Off”
(4) Set Power Switch to “ON.”
(5) Rotate the thermostat dial until the Heat
Light comes on. (It lights when the main
burner is on).
b. To Turn Off Pan
(1) Set the thermostat to "OFF".
(2) Set Power Switch to “OFF.”
(3) For a prolonged shut-off period:
(a) Set the thermostat to "OFF".
(b) Turn the main gas valve OFF (handle
at right angles to the gas pipe).
(c) Disconnect the electrical power from
the unit.
c. If Power Fails
1) Do not try to operate the unit until power is
restored.
2) When power is restored, follow directions
under “To Start Pan.”
3.
For Models with Optional Standing-Flame Pilot
(BPM-30GS, BPM-40GS)
NOTE: These models can be operated without a
115 Volt power supply. In case of a power failure,
the unit can continue to operate.
a. To Start Pan
(1) Set thermostat to "OFF".
(2) Light gas pilot.
(a) Set knob on Combination Gas Control
Valve to "OFF" by depressing the
knob slightly and turning it clockwise.
(b) Turn the main supply gas valve ON
(parallel to the gas pipe).
(c) Tilt the pan, so the pilot burner is
easier to reach.
(d) Hold a lighted match at the pilot
burner, while you depress the knob
on the Combination Control and turn
it counter-clockwise to the "PILOT"
position. Continue to hold the knob
down for 60 seconds.
(e) Release the knob. The pilot flame
should stay lighted.
(f) Turn the knob counterclockwise to
"ON".
(3) Lower the pan tilt to horizontal or cooking
position.
(4) Turn the thermostat dial to the desired
temperature.
OM-BPM-G
Содержание BPM-30S
Страница 6: ...6 OM BPM BPP G OM BPM G ...
Страница 18: ...18 OM BPM BPP G Gas Piping Assemblies Parts List ...
Страница 20: ...20 OM BPM BPP G Combustion Chamber and Gas Manifold Assemblies Parts List OM BPM G ...
Страница 22: ...22 OM BPM BPP G Electrical Control Components Gas Parts List OM BPM G ...
Страница 24: ...24 OM BPM BPP G Trunnion Cover Parts List OM BPM G ...
Страница 27: ...OM BPM BPP G 27 OM BPM G Power Tilt Components Gas Electronic Ignition Parts List OM BPM G ...
Страница 30: ...30 OM BPM BPP G Schematics Electronic Ignition System Manual Tilt ...
Страница 31: ...OM BPM BPP G 31 OM BPM G Schematics Electronic Ignition System Power Tilt OM BPM G ...
Страница 32: ...32 OM BPM BPP G Diagrams and Schematics Standing Pilot Ignition System ...
Страница 38: ...38 OM BPM BPP G NOTES ...