The unit should be installed in a ventilated room for efficient performance. Items which 

may obstruct or restrict the flow of air for combustion and ventilation must be removed. 

The area directly around the appliance must be cleared of all combustible materials.

1.   Installation requires connection with gas and electrical services. See items 8 to 14 

for details.

2.   To protect the unit from damage, leave it on the shipping pallet until the time of 

installation. When installation is to begin, cut the straps holding the kettle, and hoist 

the kettle straight up off the skid.

3.   Install the unit with a minimum clearance to combustible and non-combustible 

construction of six inches at the sides and six inches between the draft diverter 

and the wall. Also leave enough room for cleaning, maintenance, and service.

4.   The draft diverter shipped with the kettle is the correct height and shape to give 

maximum performance. Install the draft diverter as shown on the figures at left. 

Securely fasten the screw to attach draft directly. Do not change the diverter in 

any way. Install the unit under a ventilation hood, or vent the flue directly to a 

masonry chimney. Put a hood at least several inches above the upper end of the 

draft diverter. Do not rest hood supports on the diverter. Installation of a ventilating 

hood should comply with local codes and/or ANSI/NFPA-96 Latest Edition. Also, 

local codes may require that the kettle be electrically interlocked to shut off the gas 

supply and prevent the operation of the unit if the exhaust fan is not operating or 

if the fire suppression system is activated. Failure to follow these instructions can 

cause bodily injury and/or property damage.

5.   To level the unit, adjust leg length by turning the bullet feet.

6.   Make sure the water level is correct in the jacket, by confirming that the level 

is between the marks on the gauge glass. If the water level is low, follow the 

instructions under “Jacket Filling” in the “Maintenance” Section of this manual.

7.   To protect personnel from steam coming out of the safety valve, the open end of 

the elbow at the outlet must be directed down. If it is not, turn the elbow to the 

correct position.

8.  Provide 115 VAC, 60 HZ, 1 PH, 15 AMP electrical service for standard unit.  Unit 

may be equipped for alternate electrical service of 208 VAC or 240 VAC, as ordered.  

Use 1/2 inch waterproof conduit and waterproof connections.  Observe local codes 

and/or The National Electrical Code in accordance with ANSI/NFPA 70 - latest 

edition.  AN ELECTRICAL GROUND IS REQUIRED.  The electrical schematic is 

located on the inside of the service panel.

 

In Canada, provide electrical service in accordance with the Canadian Electrical 

Code, CSA C22.1 Part 1 and/or local codes.

9.  The internal gas lines of the unit were cleaned and closed off with a gas cock 

before the unit was shipped from the factory.  Free all external gas lines of lint, dirt, 

metal chips, sealant, grease, oil, and other contaminants, before you connect the 

lines to the kettle.

10.  Connect the gas cock of the kettle to the gas service main with 3/4 inch IPS line or 

approved equivalent.

Installation

WARNING 

THIS PRODUCT MUST BE INSTALLED 

BY A LICENSED PLUMBER OR GAS 

FITTER WHEN INSTALLED WITHIN THE 

COMMON WEALTH OF MASSACHUSETTS. 

IMPROPER INSTALLATION CAN CAUSE 

INJURY TO PERSONNEL AND/OR DAMAGE 

TO THE EQUIPMENT. THIS UNIT IS FOR 

COMMERCIAL USE. NEVER USE HOME OR 

RESIDENTIAL GRADE GAS CONNECTIONS.

THEY DO NOT MEET GAS CODES AND 

COULD BE HAZARDOUS.

NOTICE

TO AVOID DAMAGING PARTS OF THE 

BURNER SYSTEM UNDERNEATH THE 

KETTLE, LIFT THE UNIT ONLY BY THE

RING BENEATH THE OUTER 

PORTION OF THE BODY.

CAUTION

DO NOT CONNECT ANY PIPING TO THE

PRESSURE RELIEF SAFETY VALVE. 

IT MUST BE FREE TO VENT STEAM 

AS NEEDED. ELBOW SHOULD POINT 

DOWN TOWARD FLOOR. IMPROPER 

INSTALLATION WILL VOID WARRANTY!

DANGER 

ELECTRICALLY GROUND THE UNIT

AT THE TERMINAL PROVIDED. FAILURE TO

GROUND UNIT COULD RESULT IN

ELECTROCUTION AND DEATH.

Содержание AH/1E Domestic

Страница 1: ...pany and your authorized service agent Evacuate all personnel from the area WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Readthe...

Страница 2: ...T IN ELECTROCUTION AND DEATH CAUTION BE SURE ALL OPERATORS READ UNDERSTAND AND FOLLOW THE OPERATING INSTRUCTIONS CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL CAUTION DO NOT OVER FILL THE...

Страница 3: ...NG INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT SUCH AS A FORKLIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTAL...

Страница 4: ...27 Service Log page 28 CSA AMERICA INC 8501 East Pleasant Valley Road Cleveland Ohio 44131 ANSI Z83 11 NSF INTERNATIONAL 798 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48113 0140 NSF ANSI 4 NATION...

Страница 5: ...ric power for the unit and the thermostat to set the cooking temperature The automatic controls and a brief description of each are as follows 1 Gas pressure regulator Protects the unit from high pres...

Страница 6: ...6 Gallon etch marks 7 Flanged feet Equipment Description Model Kettle Capacity Jacket Capacity Kettle Inside Diameter Kettle Depth Overall Width Front to Back Rim Height AH 1E 20 20 Gallon 75 liter 4...

Страница 7: ...rom the skid Pull the box up off the unit taking care to avoid damage or injury from any staples left in the box walls When installation is to begin cut the straps holding the kettle to the skid and l...

Страница 8: ...n the gauge glass If the water level is low follow the instructions under Jacket Filling in the Maintenance Section of this manual 7 To protect personnel from steam coming out of the safety valve the...

Страница 9: ...yelet provided at the back of the frame and anchoring the cable or chain to the wall or floor Make the length and location of the cable such that the unit cannot pull on the gas connection while the c...

Страница 10: ...anual Begin heating the water at the highest thermostat setting The indicator light should come on and heating should continue until the water boils 7 To turn off the unit follow To Stop Kettle Heatin...

Страница 11: ...see Jacket Vacuum in the Maintenance section of this manual c DO NOT attempt to light any burner with a flame d Open main supply gas valve handle in line with the pipe e Turn the toggle switch to ON F...

Страница 12: ...hich is approximately 1 4 6 mm This incudes rice and small pasta shapes b Tips for use 1 Allow for water displacement by the baskets and product to be cooked This may mean only filling the kettle half...

Страница 13: ...rator sets a temperature on the thermostat it causes the automatic valve to admit gas to the main burner where it is ignited by the pilot flame When the kettle reaches the set temperature the thermost...

Страница 14: ...ter then drain completely 7 When you reassemble the draw off valve HAND TIGHTEN the nut which holds it in place 8 As part of the daily cleaning program clean soiled external and internal surfaces Reme...

Страница 15: ...removing mineral deposits or a film left by hard water or food residues clean the kettle thoroughly and then use a deliming agent in accordance with the manufacturer s directions Rinse and drain the...

Страница 16: ...ith cold This will condense steam in the kettle jacket and the pressure gauge should show a reading of 20 to 30 inches mercury Hg below zero If it does not or if the vacuum is leaking down contact an...

Страница 17: ...se the valve and reinstall the square head pipe plug 6 Reestablish the jacket vacuum as described above If the pressure gauge does not show a negative reading of 20 to 30 inches mercury Hg D Water Tre...

Страница 18: ...e If the valve pops at pressures below 29 PSI replace X Burners will not light User a That the main gas supply valve is open handle is in line with the gas pipe b Gas supply to the building Auth Servi...

Страница 19: ...Pilot lights but main burner will not come on the spark stays on Auth Service Rep Only a Check for bad burner ground If necessary repair with high temperature wire X b Pilot burner ceramic insulator f...

Страница 20: ...2 1 4 008350 CHAIN SINGLE JACK LINK 16 600 LONG 009009 SCREW SHEET METAL PAN HD 12 X 1 2 LG 008769 BRACKET FAUCET MOUNTING 16 GA X 4 3 4 009054 DIVERTER DRAFT 6 20 40 GALLON 012474 DIVERTER DRAFT 7 60...

Страница 21: ...4185 TEE 1 2 NPT 008772 VALVE SWING CHECK 1 2 NPT 004187 NIPPLE 1 2 NPT X CLOSE 008877 VALVE GATE 1 2 NPT 004180 LABEL WARNING 098171 WIRING DIAGRAM LABEL 123863 HARNESS WIRING 123864 NUT HEX 3 8 16 0...

Страница 22: ...000280 8 ORIFICE PROP 40 GALLON HIGHER ELEV 000281 9 BRACKET PILOT BURNER MOUNTING 123824 10 SCREW 10 24 X 3 8 LG ROUND HEAD 006009 11 PILOT BURNER ASSY 20 GALLON 0 1500 EL 096705 11 PILOT BURNER ASSY...

Страница 23: ...398 10 ORIFICE N G 0 1500 ELEV 000399 10 ORIFICE PROP HIGHER ELEV 000403 11 BRACKET PILOT BURNER MOUNTING 123824 12 SCREW 10 24 X 3 8 LG ROUND HEAD 006009 13 PILOT BURNER ASSY 0 1500 ELEV 096705 13 PI...

Страница 24: ...TURAL GAS 175442 1 BURNER ASSEMBLY AH 60 80 100 PROPANE 175452 2 PILOT BRACKET AHS 40 139181 3 ASM PILOT BURNER NATURAL GAS 102258 3 ASM PILOT BURNER PROPANE 104392 4 TUBE PILOT 139833 5 CABLE HI VOLT...

Страница 25: ...OM AH 1 25 Parts List...

Страница 26: ...26 OM AH 1 Parts List AH 20 40 GAS PIPING TO BURNER AH 60 80 100 GAS PIPING TO BURNER...

Страница 27: ...LOW WATER PROBE 101143 37 NUT KEPS 10 32 W SHAKEPROOF WASHER 071256 38 ELBOW 1 2 NPT STREET 90 004185 39 UNION 1 2 NPT 004186 40 NIPPLE 1 2 NPT x 15 80 100 40 NIPPLE 1 2 NPT x 14 60 Key Description P...

Страница 28: ...28 OM AH 1 Electrical Schematic...

Страница 29: ...OM AH 1 29 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 30: ...30 OM AH 1 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 31: ...OM AH 1 31...

Страница 32: ...REV K 12 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2016 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary of...

Отзывы: