8 OM-AH/1
The unit should be installed in a ventilated room for efficient performance. Items which
may obstruct or restrict the flow of air for combustion and ventilation must be removed.
The area directly around the appliance must be cleared of all combustible materials.
1. Installation requires connection with gas and electrical services. See items 8 to 14
for details.
2. To protect the unit from damage, leave it on the shipping pallet until the time of
installation. When installation is to begin, cut the straps holding the kettle, and hoist
the kettle straight up off the skid.
3. Install the unit with a minimum clearance to combustible and non-combustible
construction of six inches at the sides and six inches between the draft diverter
and the wall. Also leave enough room for cleaning, maintenance, and service.
4. The draft diverter shipped with the kettle is the correct height and shape to give
maximum performance. Install the draft diverter as shown on the figures at left.
Securely fasten the screw to attach draft directly. Do not change the diverter in
any way. Install the unit under a ventilation hood, or vent the flue directly to a
masonry chimney. Put a hood at least several inches above the upper end of the
draft diverter. Do not rest hood supports on the diverter. Installation of a ventilating
hood should comply with local codes and/or ANSI/NFPA-96 Latest Edition. Also,
local codes may require that the kettle be electrically interlocked to shut off the gas
supply and prevent the operation of the unit if the exhaust fan is not operating or
if the fire suppression system is activated. Failure to follow these instructions can
cause bodily injury and/or property damage.
5. To level the unit, adjust leg length by turning the bullet feet.
6. Make sure the water level is correct in the jacket, by confirming that the level
is between the marks on the gauge glass. If the water level is low, follow the
instructions under “Jacket Filling” in the “Maintenance” Section of this manual.
7. To protect personnel from steam coming out of the safety valve, the open end of
the elbow at the outlet must be directed down. If it is not, turn the elbow to the
correct position.
8. Provide 115 VAC, 60 HZ, 1 PH, 15 AMP electrical service for standard unit. Unit
may be equipped for alternate electrical service of 208 VAC or 240 VAC, as ordered.
Use 1/2 inch waterproof conduit and waterproof connections. Observe local codes
and/or The National Electrical Code in accordance with ANSI/NFPA 70 - latest
edition. AN ELECTRICAL GROUND IS REQUIRED. The electrical schematic is
located on the inside of the service panel.
In Canada, provide electrical service in accordance with the Canadian Electrical
Code, CSA C22.1 Part 1 and/or local codes.
9. The internal gas lines of the unit were cleaned and closed off with a gas cock
before the unit was shipped from the factory. Free all external gas lines of lint, dirt,
metal chips, sealant, grease, oil, and other contaminants, before you connect the
lines to the kettle.
10. Connect the gas cock of the kettle to the gas service main with 3/4 inch IPS line or
approved equivalent.
Installation
WARNING
THIS PRODUCT MUST BE INSTALLED
BY A LICENSED PLUMBER OR GAS
FITTER WHEN INSTALLED WITHIN THE
COMMON WEALTH OF MASSACHUSETTS.
IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE
TO THE EQUIPMENT. THIS UNIT IS FOR
COMMERCIAL USE. NEVER USE HOME OR
RESIDENTIAL GRADE GAS CONNECTIONS.
THEY DO NOT MEET GAS CODES AND
COULD BE HAZARDOUS.
NOTICE
TO AVOID DAMAGING PARTS OF THE
BURNER SYSTEM UNDERNEATH THE
KETTLE, LIFT THE UNIT ONLY BY THE
RING BENEATH THE OUTER
PORTION OF THE BODY.
CAUTION
DO NOT CONNECT ANY PIPING TO THE
PRESSURE RELIEF SAFETY VALVE.
IT MUST BE FREE TO VENT STEAM
AS NEEDED. ELBOW SHOULD POINT
DOWN TOWARD FLOOR. IMPROPER
INSTALLATION WILL VOID WARRANTY!
DANGER
ELECTRICALLY GROUND THE UNIT
AT THE TERMINAL PROVIDED. FAILURE TO
GROUND UNIT COULD RESULT IN
ELECTROCUTION AND DEATH.