Groen AH/1E Domestic Скачать руководство пользователя страница 6

6 OM-AH/1

The kettle body is welded into one piece and has a rim reinforced by a rectangular bar.  
The interior and exterior of the kettle is polished to a 180 emery grit finish.  The unit is 
ASME shop inspected and registered with the National Board for working pressures up 
to 30 PSI.

The standard 2 inch tangent draw-off is a 316 stainless steel, compression disc valve.  
A removable strainer with 1/4 inch holes keeps pieces of product from entering the 
draw-off during cooking.

The jacket is filled at the factory with water containing rust inhibitors.  The kettle can 
operate at steam pressures up to 30 PSI, which provide temperatures of 150°F (65°C) 
to approximately 270°F (135°C).  This range allows warming, simmering, boiling, or 
braising.

For the kettles, options include:

1.  Larger (3 inch) draw-off
2.  Solid disc strainer or strainer with 1/8 inch perforations
3.  Water fill faucets
4.  Basket inserts
5.  Kettle brush kit
6.  Gallon etch marks
7.  Flanged feet

Equipment Description

Model

Kettle

Capacity

Jacket

Capacity

Kettle 

Inside

Diameter

Kettle 

Depth

Overall Width

Front-to-Back

Rim Height

AH/1E-20

20 Gallon

(75 liter)

4-1/2 Gallon

(17 liter)

20 inches

(508 mm)

18 inches

(457 mm)

36-3/4 inches

(934 mm)

39 inches

(991 mm)

40 inches

(1016 mm)

AH/1E-40

40 Gallon

(150 liter)

7 Gallon

(26.5 liter)

26 inches

(660 mm)

22 inches

(559 mm)

38-1/4 inches

(972 mm)

45 inches

(1143 mm)

42 inches

(1067 mm)

AH/1E-60

60 Gallon

(225 liter)

9-1.2 Gallon

(36 liter)

30 inches

(762 mm)

25 inches

(635 mm)

41 inches

(1041 mm)

49 inches

(1245 mm)

49 inches

(1245 mm)

AH/1E-80

80 Gallon

(300 liter)

11-1/2 Gallon

(43.5 liter)

32 inches

(813 mm)

29 inches

(737 mm)

42-1/2 inches

(1080 mm)

51 inches

(1295 mm)

55-1/2 inches

(1410 mm)

AH/1E-100

100 Gallon

(375 liter)

11-1/2 Gallon

(43.5 liter)

32 inches

(813 mm)

35 inches

(889 mm)

42-1/2 inches

(1080 mm)

51 inches

(1295 mm)

61-1/2 inches

(1562 mm)

Model

Ignition

FIRING RATE, BTU/HOUR

Natural Gas

Propane Gas

AH/1E-20

Spark

85,000

85,000

AH/1E-40

Spark

100,000

85,000

AH/1E-60

Spark

145,000

145,000

AH/1E-80

Spark

145,000

145,000

AH/1E-100

Spark

145,000

145,000

Содержание AH/1E Domestic

Страница 1: ...pany and your authorized service agent Evacuate all personnel from the area WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Readthe...

Страница 2: ...T IN ELECTROCUTION AND DEATH CAUTION BE SURE ALL OPERATORS READ UNDERSTAND AND FOLLOW THE OPERATING INSTRUCTIONS CAUTIONS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL CAUTION DO NOT OVER FILL THE...

Страница 3: ...NG INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT SUCH AS A FORKLIFT DOLLY OR PALLET JACK TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTAL...

Страница 4: ...27 Service Log page 28 CSA AMERICA INC 8501 East Pleasant Valley Road Cleveland Ohio 44131 ANSI Z83 11 NSF INTERNATIONAL 798 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48113 0140 NSF ANSI 4 NATION...

Страница 5: ...ric power for the unit and the thermostat to set the cooking temperature The automatic controls and a brief description of each are as follows 1 Gas pressure regulator Protects the unit from high pres...

Страница 6: ...6 Gallon etch marks 7 Flanged feet Equipment Description Model Kettle Capacity Jacket Capacity Kettle Inside Diameter Kettle Depth Overall Width Front to Back Rim Height AH 1E 20 20 Gallon 75 liter 4...

Страница 7: ...rom the skid Pull the box up off the unit taking care to avoid damage or injury from any staples left in the box walls When installation is to begin cut the straps holding the kettle to the skid and l...

Страница 8: ...n the gauge glass If the water level is low follow the instructions under Jacket Filling in the Maintenance Section of this manual 7 To protect personnel from steam coming out of the safety valve the...

Страница 9: ...yelet provided at the back of the frame and anchoring the cable or chain to the wall or floor Make the length and location of the cable such that the unit cannot pull on the gas connection while the c...

Страница 10: ...anual Begin heating the water at the highest thermostat setting The indicator light should come on and heating should continue until the water boils 7 To turn off the unit follow To Stop Kettle Heatin...

Страница 11: ...see Jacket Vacuum in the Maintenance section of this manual c DO NOT attempt to light any burner with a flame d Open main supply gas valve handle in line with the pipe e Turn the toggle switch to ON F...

Страница 12: ...hich is approximately 1 4 6 mm This incudes rice and small pasta shapes b Tips for use 1 Allow for water displacement by the baskets and product to be cooked This may mean only filling the kettle half...

Страница 13: ...rator sets a temperature on the thermostat it causes the automatic valve to admit gas to the main burner where it is ignited by the pilot flame When the kettle reaches the set temperature the thermost...

Страница 14: ...ter then drain completely 7 When you reassemble the draw off valve HAND TIGHTEN the nut which holds it in place 8 As part of the daily cleaning program clean soiled external and internal surfaces Reme...

Страница 15: ...removing mineral deposits or a film left by hard water or food residues clean the kettle thoroughly and then use a deliming agent in accordance with the manufacturer s directions Rinse and drain the...

Страница 16: ...ith cold This will condense steam in the kettle jacket and the pressure gauge should show a reading of 20 to 30 inches mercury Hg below zero If it does not or if the vacuum is leaking down contact an...

Страница 17: ...se the valve and reinstall the square head pipe plug 6 Reestablish the jacket vacuum as described above If the pressure gauge does not show a negative reading of 20 to 30 inches mercury Hg D Water Tre...

Страница 18: ...e If the valve pops at pressures below 29 PSI replace X Burners will not light User a That the main gas supply valve is open handle is in line with the gas pipe b Gas supply to the building Auth Servi...

Страница 19: ...Pilot lights but main burner will not come on the spark stays on Auth Service Rep Only a Check for bad burner ground If necessary repair with high temperature wire X b Pilot burner ceramic insulator f...

Страница 20: ...2 1 4 008350 CHAIN SINGLE JACK LINK 16 600 LONG 009009 SCREW SHEET METAL PAN HD 12 X 1 2 LG 008769 BRACKET FAUCET MOUNTING 16 GA X 4 3 4 009054 DIVERTER DRAFT 6 20 40 GALLON 012474 DIVERTER DRAFT 7 60...

Страница 21: ...4185 TEE 1 2 NPT 008772 VALVE SWING CHECK 1 2 NPT 004187 NIPPLE 1 2 NPT X CLOSE 008877 VALVE GATE 1 2 NPT 004180 LABEL WARNING 098171 WIRING DIAGRAM LABEL 123863 HARNESS WIRING 123864 NUT HEX 3 8 16 0...

Страница 22: ...000280 8 ORIFICE PROP 40 GALLON HIGHER ELEV 000281 9 BRACKET PILOT BURNER MOUNTING 123824 10 SCREW 10 24 X 3 8 LG ROUND HEAD 006009 11 PILOT BURNER ASSY 20 GALLON 0 1500 EL 096705 11 PILOT BURNER ASSY...

Страница 23: ...398 10 ORIFICE N G 0 1500 ELEV 000399 10 ORIFICE PROP HIGHER ELEV 000403 11 BRACKET PILOT BURNER MOUNTING 123824 12 SCREW 10 24 X 3 8 LG ROUND HEAD 006009 13 PILOT BURNER ASSY 0 1500 ELEV 096705 13 PI...

Страница 24: ...TURAL GAS 175442 1 BURNER ASSEMBLY AH 60 80 100 PROPANE 175452 2 PILOT BRACKET AHS 40 139181 3 ASM PILOT BURNER NATURAL GAS 102258 3 ASM PILOT BURNER PROPANE 104392 4 TUBE PILOT 139833 5 CABLE HI VOLT...

Страница 25: ...OM AH 1 25 Parts List...

Страница 26: ...26 OM AH 1 Parts List AH 20 40 GAS PIPING TO BURNER AH 60 80 100 GAS PIPING TO BURNER...

Страница 27: ...LOW WATER PROBE 101143 37 NUT KEPS 10 32 W SHAKEPROOF WASHER 071256 38 ELBOW 1 2 NPT STREET 90 004185 39 UNION 1 2 NPT 004186 40 NIPPLE 1 2 NPT x 15 80 100 40 NIPPLE 1 2 NPT x 14 60 Key Description P...

Страница 28: ...28 OM AH 1 Electrical Schematic...

Страница 29: ...OM AH 1 29 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 30: ...30 OM AH 1 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Страница 31: ...OM AH 1 31...

Страница 32: ...REV K 12 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2016 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary of...

Отзывы: