PART NUMBER 152797 REVISION A
CALL 888-994-7636 FOR TECHNICAL SUPPORT
30
6. Close the door until the latch pin just penetrates the mask-
ing tape. Make sure the door pin contacts only the door latch
spring.
7. If door pin does not strike the center of the masking tape
or spring hole in the U-channel, loosen the hinge-to-oven bolts
and align the door to the door pin. Tighten-to-oven mounting
bolts.
8. You should be able to pull a dollar bill or comparable piece
of paper with some effort, from between the gasket and Tri-Res
cavity with the door closed. To adjust the hinge side, loosen the
door-to-hinge bolts and align the door gasket with the oven
cavity. Tighten the door-to-hinge mounting bolts.
9. Operate Tri-Res and check for leaks.
5.8 Door Switch
P/N 096857
Note:
One normally open door switch is factory-installed on
one side of the control panel housing. It is activated (that is,
closed) by the proximity of the door magnet.
1. Remove the side panel and the control panel housing for
access to the door switch that is to be replaced.
2. Unplug the door switch from the Tri-Res harness.
3. The switch is held in place with two small 4-40 screws. With
a slotted screwdriver, remove these screws and the switch may
be removed.
4. To install the switch use the two 4-40 screws and a screw-
driver with a screwstarter features.
5. Connect switch leads to steamer harness.
6. Replace control panel housing and side panel.
7. Test Tri-Res operation.
5.9 Door Gasket
For Part Number see Parts Identification Section.
NOTE:
Door gasket not covered under terms of warranty
Removal
1. Turn off Tri-Res power and allow to cool.
2. Remove the door using one of the following two methods:
a) Support the door and remove hinge pin or
b) Support weight of the door and remove the two door-to-
hinge bolts.
3. Place the door on flat, clean, smooth table or similar support
with handle hanging over edge. Be careful not to scratch the
door.
4. Remove four (or eight) 8-32 truss head screws and remove
inner door panel.
5. Remove and discard door gasket.
6. Clean back of the inner door panel. Be sure old sealant is
completely removed.
Installation
1. Install new door gasket around inner panel as shown in the
illustration. Be sure the inner door panel flange is full inserted
into the door gasket groove.
2. Apply a high temperature silicone sealant, such as gE RTV
159 or equivalent, to the four door spacers.
3. Apply Locktite 242 to inner door panel mounting screws.
4. Install inner door panel and door gasket on the door spac-
ers, and tighten mounting screws.
5. Align door with hinge and insert hinge pin OR apply Locktite
242 to the door-to-hinge bolts, then install door and mounting
bolts. Do NOT tighten mounting bolts at this time.
6. Align door to Tri-Res and tighten bolts.
Please refer to 4.8 for alignment procedure.
5.10 Water Level Probe
Removal
1. Turn off the Tri-Res power and disconnect the Tri-Res from
the branch circuit.
2. Remove the rear cover from the Tri-Res.
3. Disconnect the water level probe harness wire.
4. Loosen and remove the hex locking nut and washer.
5. Remove the probe.
Installation
6. Insert the new water level probe.
7. From the outside, put on any washer and locking nut.
Tighten nut finger tight and then another 1/4 turn to prevent
any water leaks.
8. Attach the harness wire.
9. Turn on the branch circuit power supply.
10. Turn ON the Tri-Res and test.
assembly/dIsassembly
Содержание 2TRI-RES-20G
Страница 40: ...PART NUMBER 152797 REVISION A CALL 888 994 7636 FOR TECHNICAL SUPPORT 40 Wiring Diagram ...
Страница 41: ...PART NUMBER 152797 REVISION A CALL 888 994 7636 FOR TECHNICAL SUPPORT 41 Ladder Diagram ...
Страница 43: ......
Страница 44: ... ENDELL AVIS RIVE s ACKSON 3 s s AX GROEN COM 0 24 5 2 PART NUMBER 152797 REVISION A ...