PART NUMBER 152797 REVI-
SION A
CALL 888-994-7636 FOR TECHNICAL SUPPORT
14
CAUTION
When the unit is moved from its original position for
cleaning or service, the hooks on the restraining cable
assembly must be reconnected at both ends. Detailed
Instructions for the re-connection to the appliance are
shown below under Unit Restraining Requirement.
Unit Restraining Requirement:
A. The installation shall be made with a connector that com-
plies with the standard for connectors for movable gas appli-
ances. ANSI Z21.69.CSA 6.16, and a quick-disconnect device
that complies with the standard for quick-disconnect devices
for use with gas fuel, ANSI Z21.41.CSA 6.9.
B. Adequate means must be provided to limit the movement
of the appliance without depending on the connector and the
quick-disconnect device or its associated piping to limit the ap-
pliance movement.
C. The location where the restraining device may be attached
to the appliance shall be in accordance with groen specifica-
tions for the device. (see photo)
D. Anchor restraining cable bracket to a secure structure.
One of the preferred locations is on the concrete floor using
anchor bolts (not provided) as shown below.
InstallIng, cleanIng and testIng
Eyebolt connector
on the back of