-54-
Model G0869/G0870 (Mfd. Since 01/19)
Fence Scale
Calibration
The fence scale indicator window, shown in
Figure 87, can be calibrated with the fence scale
if you notice that your cuts do not accurately
match what is shown on the fence scale.
The indicator adjusts by loosening the two mount-
ing screws and sliding it in the desired direction.
Items Needed
Qty
Phillips Head Screwdriver #2 ............................ 1
Scrap Piece of Wood......................................... 1
Tape Measure .................................................... 1
To calibrate fence scale indicator windows:
1. Position and lock fence at 13", as indicated
by scale, then cut your scrap piece of wood.
2. Reposition and lock fence at 12", as indicated
by scale.
3. Flip your scrap piece of wood over, placing
side that was cut in
Step 2 against fence, and
cut your scrap piece of wood.
4. Measure width of freshly cut workpiece with
tape measure. Workpiece width should be
exactly 12". If it is not, then adjust indicator
window to match the width of workpiece.
Figure 87. Fence indicator window.
Screws
Indicator Window
Table/Dado Insert
Adjustment
The table/dado insert must sit perfectly flush with
the table to provide a smooth, continuous surface
for the workpiece to slide over. The insert is held
in place by a magnet and sits on top of four adjust-
ment screws (see
Figure 88).
The insert should be checked and adjusted any
time it is removed and replaced, after prolonged
use, or any time you notice the workpiece or fence
does not slide smoothly over the insert.
Tools Needed
Qty
Hex Wrench 2.5mm ........................................... 1
Straightedge ...................................................... 1
Figure 88. Location of table/dado insert holes
with adjustment screws.
To check and adjust insert:
1. DISCONNECT MACHINE FROM POWER!
2. Place straightedge across insert and check
to make sure insert is flush with table at front
and back of throat.
— If insert is flush with table, no adjustments
are necessary.
— If insert is not flush with table, proceed to
Step 3.
3. Insert hex wrench through holes shown in
Figure 88 and either loosen screws to raise
insert, or tighten screws to lower it. Repeat
Steps 2–3 until insert is perfectly flush with
surface of table.