Figure 68. G0850 performance curve chart and
data.
The airflow test probe is located 1.5x duct diameter upstream from
the air inlet. Test pipe length is a minimum of 10x duct diameter.
5 HP GRIZZLY DUST COLLECTOR PERFORMANCE RESULTS
Max CFM Max SP HP
Volts
Inlet
Impeller
2577
12.1
5 HP
230V
8" x 2
15
3
⁄
4
"
Restrictor Plate
Diameter (inch)
8" x 2 7" x 2 6" x 2 5" x 2 4" x 2 3" x 2 0"
Static Pressure
(Inch/H
2
O)
1.4
4.3
6.5
9.8
10.6
11.7
12.1
CFM
2577 1700 1445 1210 1025 645
200
Description
Model
Quantity
6" Rigid Duct at 20'
G7364
4
4" Rigid Duct at 10'
G6162
2
4" Flex Hose at 5'
H7215
6
6" 45
° Y-Branch
G7353
6
4" 45
° Elbow
G6167
6
Example Materials List
After the system is designed, create a materials
list of all the items you will need to build your dust
collection system. This will make it easy when it
comes time to purchase the materials.
Below is an example of some items that might be
needed. Refer to
Accessories for dust collection
components available through grizzly.com.
CFM
G0850 Performance Curve
2750
2500
2250
2000
1750
1500
1250
1000
750
500
250
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0 11.0 12.0
2577
1700
1445
1210
1025
645
200
STATIC PRESSURE (Inch/H
2
O)
Содержание G0850