Model G0850 (Mfd. Since 01/19)
-19-
16. Attach two chains or lifting straps to impeller
housing eye bolts in an "X" pattern, as shown
in
Figure 24, then use forklift or crane to lift
impeller housing enough to clear assembled
base stand and legs.
IMPORTANT: To avoid damage when hoist-
ing the impeller housing, make sure the
chains or lifting straps are long enough to
avoid contacting the magnetic switch, junc-
tion box, and motor.
Figure 24. Proper attachment of chains or lifting
straps to impeller housing.
Motor
Chains
or Lifting
Straps
HEAVY LIFT!
Straining or crushing injury
may occur from improperly
lifting machine or some of
its parts. To reduce this risk,
get help from other people
and use a forklift (or other
lifting equipment) rated for
weight of this machine.
17. While two assistants align legs below impel-
ler housing, slowly lower it so legs slide into
slots on outside of housing (see
Figure 25).
DO NOT work under any load without a
secondary support system. Machine is top
heavy. To keep machine stable, DO NOT
remove lifting equipment until directed to
do so.
Figure 25. Supporting impeller housing to attach
to legs.
Slots
(2 of 4)
18. Attach impeller housing to center and outer
legs with (10)
5
⁄
16
"-18 x
3
⁄
4
" hex bolts and (10)
5
⁄
16
" flat washers (see
Figure 26).
Figure 26. Attach motor/impeller housing to legs
at five locations.
x 10
19. Final tighten all fasteners installed through
Step 18. Double-check that all are secure.
20. Remove lifting equipment carefully without
damaging electrical components.
21. Remove control panel and filter cleaning
motors from packaging and set aside on
impeller housing for now.
Magnetic
Switch
Junction
Box
Outer
Legs
(2 of 4)
Impeller
Housing
Содержание G0850