10. Install power feed unit onto right side of
bracket assembly and temporarily tighten hex
bolts (see
Figure 24).
11. Move power feed unit until power feed gear
teeth align with X-axis leadscrew gear teeth,
then tighten cap screws from
Step 8 (see
Figure 24).
12. Loosen hex bolts from Step 10, adjust power
feed unit until power feed gear meshes with
X-axis leadscrew gear, then fully tighten hex
bolts (see
Figure 24).
Figure 24. Left side of power feed bracket with
attached power feed unit mounted to right side of
bracket.
Hex Bolt
(1 of 2)
Power Feed
Gear
Cap Screw
(1 of 2)
X-Axis
Leadscrew
Gear
15. Loosen and remove factory-installed limit
stops, then insert both accessory limit stop
assemblies into groove in table, as shown in
Figure 26.
16. Slide one limit stop all the way to left end of
table, and slide the other stop all the way to
right end.
Figure 26. Accessory limit stop assembly
mounted in table groove (1 of 2 shown).
Accessory Limit Stop
Assembly (1 of 2)
Groove
13. Install direction lever handle, as shown in
Figure 25.
14. Remove adhesive backing from gear guard
and install over X-axis table gear, as shown
in
Figure 25.
Figure 25. Gear cover installed.
Gear
Guard
Handle
17. Remove factory-installed stop plate, then
use its mounting screws to install limit switch
mounting block in its place (see
Figure 27).
18. Install X-axis limit switch to mounting block
using (2) included M8-1.25 x 12 cap screws
and 8mm flat washers (see
Figure 27).
Figure 27. X-axis limit switch installed.
x 2
Mounting
Block
X-Axis
Limit Switch