Test Run
Once assembly is complete, test run your machine
to make sure it runs properly and is ready for
regular operation.
The test run consists of verifying the following:
1) The motor powers up and runs correctly,
2) the spindle switch works correctly, and 3)
(G0797 only) the motor turns the correct direction
(machine is not wired out of phase).
If, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review
Troubleshooting on Page 51.
If you still cannot remedy a problem, contact our
Tech Support at (570) 546-9663 for assistance.
1. Make sure you understand all safety instruc-
tions at beginning of manual and that machine
is set up properly.
2. Make sure all tools and objects used during
setup are cleared away from machine.
3. Make sure that mill is properly lubricated
(refer to
Lubrication section on Page 47 for
specific details).
4. Set spindle speed to low range (refer to
Spindle Speed, beginning on Page 34 for
detailed instructions).
5. Move downfeed selector to manual (for-
ward) position so that spindle does not auto-
matically downfeed during this test (refer to
Downfeed Controls section on Page 37 for
detailed instructions).
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
6. Rotate spindle switch to STOP (G0796) or
OFF (G0797) to avoid accidental startup in
Step 7.
7. Connect mill to power source specified in
POWER SUPPLY section on Page 17.
8. Rotate spindle switch to FOR (forward) posi-
tion (see
Figure 20 or 21).
Mill Test Run
Figure 20. Model G0796 spindle switch.
Figure 21. Model G0797 spindle switch.
Spindle Switch
FWD
Position
Spindle Switch
FOR
Position
9. Listen for abnormal noises and watch for
unexpected actions from mill. Machine should
run smoothly and without excessive vibration
or rubbing noises.
— Strange or unusual noises or actions must
be investigated immediately. Turn the
machine
OFF and disconnect it from the
power source before investigating or cor-
recting potential problems.
10. Rotate spindle switch to STOP (G0796) or
OFF (G0797) to stop spindle rotation.