-30-
Model G0580 (Mfd. Since 11/06)
The miter gauge needs to be calibrated to the
blade when it is first mounted in the miter slot.
Refer to
Blade Lead on Page 52 for more infor-
mation about typical bandsaw cutting habits.
Tools
Needed: Qty
Machinist's Square ............................................ 1
Phillips Screwdriver ........................................... 1
To calibrate the miter gauge:
1. Use a machinist's square with one edge
against the face of the miter gauge and the
other against the blade face, as shown in
Figure 40.
Figure 40. Squaring miter gauge to blade.
Miter Gauge
2. Loosen the lock knob on the miter gauge and
adjust it flush with the edge of the square.
3. Tighten the lock knob, and verify the setting.
Note: Sometimes the tightening procedure
can affect the adjustment.
4. Loosen the screw that secures the angle
pointer and adjust the pointer to the 0˚ mark
on the scale.
5. Retighten the screw that secures the angle
pointer.