www.greyline.com
8.
Scroll down through the menu list and
enter/change the pipe parameters and other data
pertaining to the site.
Note that this menu allows you to choose a
Sensor Set, unlike the QUICK START menu
which recommended the sensor set to use. If you
enter an inappropriate sensor set in this menu you
will be presented with an error message later
when you go to the SENSOR SEPARATION
screen.
VIEW EDIT SITE DATA
DD-MM-YY HH:MM:SS
Dim: mm
Choose from list of sites
Site name
:
MyNewSite
Dimension units
:
mm
Pipe outside diameter
:
58.00
Pipe wall thickness
:
4.00
Pipe lining thickness
:
0.00
9.
When all the data is correct you can either:
a)
Select Save current site & read
flow to continue fitting the transducers and
opening the FLOW READING screen.
b)
Select Delete this site to delete
the site name and values and restore it to
the original EmptySite name.
c)
Select Download & save current
site to save the site details and download
them to a PC via RS232/USB provided the
RS232/USB link is connected and correctly
set-up.
d)
Select Exit to return to the MAIN
MENU.
Pipe wall material
:
Mild Steel
Lining material
:
---------
Sensor set
:
A-ST
Sensor mode
:
Reflex
Fluid type
:
Water
Save current site & read flow
Delete this Site
Download & save current site
Exit
3.4.2
Changing a site name
To change a site name use the same method described above for generating a new site: but in this case access
a current site name to change rather than an EmptySite. If you change a site name while the site is logging the