![Greyline Portaflow PT400 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/greyline/portaflow-pt400/portaflow-pt400_user-manual_2264647017.webp)
Page
17
www.greyline.com
Cast Iron
Ductile Iron
Copper
Brass
Concrete
Glass
Other (m/s)
8.
If a lining thickness value was entered earlier,
this screen is displayed to request that you enter
the lining material type. If no lining thickness was
entered this screen will be bypassed.
9.
Select the lining material from the list provided
then press ENTER.
If the material is not listed select Other and enter
the propagation rate of the lining material in
metres/sec. Contact Greyline if this is not known.
PIPE LINING MATERIAL
DD-MM-YY HH:MM:SS
Select pipe lining material
Steel
Rubber
Glass
Epoxy
Concrete
Other (m/s)
10.
Select the fluid type from the list provided and
press ENTER.
If the liquid is not listed select Other and enter a
propagation rate in metres/second.
FLUID TYPE
DD-MM-YY HH:MM:SS
Select fluid type
Water
Glycol/water 50/50
Glycol/water 30/70
Lubricating oil
Diesel
Freon
Other (m/s)
11.
If you need to alter the fluid temperature from
that shown select either °C or °F with the cursor
and press the ENTER key.
12.
Enter the new temperature value and press the
ENTER key.
13.
The new temperature should now be indicated
in both °C and °F.
14.
Select Continue.. and press ENTER.
FLUID TEMPERATURE
DD-MM-YY HH:MM:SS
Enter Fluid Temperature
°C: 5.00
°F: 41.00
Continue..
15.
The SENSOR SEPARATION screen now
displays a summary of the entered parameters and
informs you of the type of sensor to be used, the
mode of operation and the distance to set up
between the sensors.
In this example it recommends type A-ST (A
standard) sensors operating in the ‘Reflex’ mode
spaced at 32.2mm apart.
Take a note of these details
SENSOR SEPARATION
DD-MM-YY HH:MM:SS
Site
: Quickstart
Pipe
: 58.00 mm
Wall
: 4.00
Sensors
:
A-ST
Reflex
Temperature
: 10.00°C 50.00°F
Set sensor separation to
32.2 mm
Press
to continue,
to select sens.