Page 38
Multi-Sensor Area Velocity Flow Meter
SPECIFICATIONS
Electronics Enclosure:
NEMA4X (IP 66), watertight and dust tight, polycarbonate with clear,
shatterproof hinged Lexan cover
Accuracy:
Level: ± 0.25% of Range Velocity: ± 2% of Reading Repeatability: 0.1%
F.S., Linearity: 0.1%F.S.
Display:
White, backlit matrix – displays flow rate, totalizer, relay states,
operating mode and calibration menu
Programming:
Built-in 5-key calibrator with English, French or Spanish language
selection
Power Input:
100-240VAC, 50/60 Hz, (30 W max.)
Optional: 9-32VDC (9 W max.)
Outputs:
3 Isolated 4-20mA, 1000 ohm load maximum or 3 Isolated 0-5V
Control Relays:
Qty 2, rated 5 ampere SPDT
Temperature Compensation:
Automatic, temperature probe built in to level Sensor
Electrical Surge Protection:
Sensor, 4-20mA, AC power input
Environmental Conditions:
Relative humidity up to 80% -23 to 60°C ambient temperature,
maximum 5000 m altitude, pollution degree 4, Installation Category II.
Optional Enclosure Heater recommended for condensation protection
below 32°F (-1°C)
7.4 /
1
88 mm
"
6.46 /
1
64 mm
"
1
0.94
"/
278 mm
1
0
/ 254 mm
"
CONDUIT ENTRY
LOCATION
SIDE VIEW
5.
1
2 /
1
30 mm
"
AV
MS 1
5.
Multi-Sensor
A
rea
V
elo
c
it
y
Flo
w
Meter