Page 19
Multi-Sensor Area Velocity Flow Meter
SIMULATION
Exercises the 4-20mA (0-5V) outputs, digital display and control relays.
Test
Select
Maximum
and press
to simulate maximum Flow, Level and
Velocity and to output 20mA (5V) to the analog channels.
Select
Minimum
and press
to simulate minimum Flow, Level and
Velocity and to output 4mA (0V) to the analog channels.
To simulate an intermediate Flow, Level and Velocity set
Test
to
Actual
and then enter a value for the
Level
and
Velocity
.
The Flow calculation, analog outputs and control relays will respond to
the simulated values.
--Simulation--------
Test
Actual
Level
0
.
00in
Velocity
10ft
/
s
Flow
1982
.
88USG
/
m
4-20mA Level
20
.
00
4-20mA Velocity20
.
00
4-20mA Flow
20
.
00
Relays 1 2
}