Page 14
Multi-Sensor Area Velocity Flow Meter
Min Vel
Press
and enter a minimum velocity cutoff. Forward and
reverse velocities less than
Min Vel
will be forced to
zero.
Min Vel A
Press
and enter a minimum velocity
cutoff for sensor A.
Min Vel B
Press
and enter a minimum velocity
cutoff for sensor B.
Min Vel C
Press
and enter a minimum velocity
cutoff for sensor C.
Damping
Increase damping to stabilize readings under turbulent flow
readings or to reject spurious level readings. Decrease for
faster response to changes in flow.
Press
from the
Calibration
display to return to Menu Selections.
SENSOR
END VIEW
SIDE VIEW
TOP VIEW
SENSOR
U-SHAPE STAINLESS STEEL
18 GA. RECOMMENDED
HEIGHT AS REQUIRED
USE THE MB-QZ
STAINLESS STEEL
MOUNTING BRACKET
(SUPPLIED)