Safety 

1.1  General note 

Read this document carefully and get used to the operation of the device before you use it. Keep this document within 
easy reach near the device for consulting in case of doubt.  

Mounting, start-up, operating, maintenance and removing from operation must be done by qualified, specially trained 
staff that have carefully read and understood this manual before starting any work. 

The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one, ignor-
ing this manual, operating by unqualified staff as well as unauthorized modifications to the device. The manufacturer is 
not liable for any costs or damages incurred at the user or third parties because of the usage or application of this de-
vice, in particular in case of improper use of the device, misuse or malfunction of the connection or of the device. Be-
stimmungsgemäße Verwendung 

1.2  Intended use 

Dissolved Oxygen-Measuring transducer converts an air oxygen-value in a 4-20 mA signal. 

1.3  Qualified staff 

For operating, running, maintaining and commissioning the device, the staffs needs to have an adequate level of 
knowledge of both, the measuring and the meaning of measured values. This manual can be a valuable contribution. 
All instructions have to be well-understood and complied with. To be sure that there is no risk arising due to misinter-
pretation of measured values, the operator must have further knowledge in case of doubt - the user is liable for any 
harm/damage resulting from misinterpretation due to insufficient knowledge.  
The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one, ignor-
ing this manual, operating by unqualified staff as well as unauthorized modifications to the device. 

1.4  Safety signs and symbols 

Warning notices are marked in this manual as shown below: 

 

This symbol warns of imminent danger, death, serious injuries and significant damage to prop-
erty at non-observance.

 

 

This symbol warns of danger to living tissue and many materials, that can be damaged 
or destroy by exposure to that chemical! 

 

Achtung! Symbol warnt vor möglichen Gefahren oder schädlichen Situationen, die bei Nichtbe-
achtung Schäden am Gerät bzw. an der Umwelt hervorrufen.

 

 

This symbol points out processes which can indirectly influence operation or provoke unfore-
seen reactions at non-observance.

 

 

This symbol refers of using a eye protection, which protects the eyes from strong light, UV radia-
tion, laser, chemicals, dust, splitter or weather conditions. 

 

This symbol refers of using protective gloves, which protects for mechanical-, thermal-, chemi-
cal-, biological- or electrical hazards. 

 

 

Содержание OXY 3610 MP

Страница 1: ...3X 6C 07 Operating Manual Dissolved Oxygen Measuring transducer OXY 3610 MP Keep for later use www ghm group de Companies Brands of the GHM Englisch...

Страница 2: ...OF THE OXYGEN MEASURING TRANSDUCER 8 7 CONFIGURATION OF THE DEVICE 8 7 1 CONFIGURATION PROCEDURE 8 7 1 1 OFFSET OFFS 8 7 1 2 Average ambient absolute pressure PABS 9 7 1 3 Display damping FiLT 9 7 1 4...

Страница 3: ...asured values This manual can be a valuable contribution All instructions have to be well understood and complied with To be sure that there is no risk arising due to misinter pretation of measured va...

Страница 4: ...h large amounts of water for several minutes To clothing remove contaminated clothing To eyes Flush with large amounts of water for at least 15 minutes obtain medical treatment After swallowing Give l...

Страница 5: ...repair or maintenance With costs The conceptual design particularly when connecting with other devices has to be done thor oughly Internal connections of other devices e g from ground with protective...

Страница 6: ...sealing cable fitting b shim c and sealing ring d Pull out the connection socket f Thread cable through parts b c d and into connector housing e To mount the connection cable 2 3 or 4 wire depending...

Страница 7: ...normal operation the oxygen content is displayed in the unit mg l By pressing the Key 2 down the temper ature at the electrode can be shown pressing key 3 up shows the state of the electrode in The st...

Страница 8: ...k Calibration surrounding Oxygen electrodes are sensitive components Please read the referring manual prior to use During calibration the rating of the electrode is evaluated 100 means perfect state 4...

Страница 9: ...8888 The values will be saved The device will start again The display is shown 8888 Bring back the jumper j1 to the parking position after configuration one contact connected the second contact on air...

Страница 10: ...uction of the sensor GWO 3600 11 1 1 General The oxygen electrode is an active electrode consisting of a silver cathode and a lead anode using potassium hydrox ide KOH as an electrolyte In case of oxy...

Страница 11: ...ements This may also be the reason for errors in the calibration The membrane head is a spare part and can be ordered individually o Filling hole If the electrode is used at high temperatures or if it...

Страница 12: ...d vertically from above till the thread catches Then take up head with paper towel and screw onto electrode from underneath Electrolyte will be displaced from the membrane head flowing over Mop up exc...

Страница 13: ...2 years at nominal condition Display 1 5 of measured value 0 2 mg l Output signal 0 2 FS Connection 4 20 mA Zweileiter Spannung Dreileiter bzw Vierleiter Add output signal 0 2 FS Auxiliary energy sup...

Страница 14: ...x 80 x 55 mm without elbow type plug and sensor sockets Mounting With fixing holes for wall mounting in housing accessible after cover has been removed Mounting distance 50 x 70mm max shaft diameter...

Отзывы: