2.
If there is a risk whatsoever involved in running it, the device has to be switched off
immediately and to be marked accordingly to avoid re-starting.
Operator safety may be a risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer time.
In case of doubt, please return device to manufacturer for repair or maintenance.
3. When connecting the device to other devices the connection has to be designed most thoroughly as
internal connections in third-party devices (e.g. connection GND with protective earth) may lead to
undesired voltage potentials that can lead to malfunctions or destroying of the instrument and the
connected devices.
This device must not be run with a defective or damaged power supply unit.
Danger to life due to electrical shock!
4.
Do not use these products as safety or emergency stop devices or in any other application
where failure of the product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material
damage.
5.
This device must not be used at potentially explosive areas! The usage of this device at
potentially explosive areas increases danger of deflagration, explosion or fire due to
sparking.
3
Product Specification
3.1 Scope of supply
The scope of supply includes:
GMH 5430 with 2 AAA batteries
Operating manual
Short form manual
3.2 Operation and maintenance advice
1. Temperature measuring / sensor connection:
There is the possibility to connect a temperature sensor (Pt1000 or NTC 10k) to the 7-pole bayonet
socket. Generally a suitable temperature sensor is included to the measuring cell. The measured
temperature is used for the automatic temperature compensation (e.g. Lin or nlF) and is additionally
displayed.
2. Battery operation:
If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced. However,
the device will operate correctly for a certain time. If ‘bAt’ is shown in the upper display the voltage is too
low to operate the device; the battery has been completely used up. Battery change: p.r.t. chapter 13.
The battery has to be taken out, when storing device above 50°C. We recommend taking out
battery if device is not used for a longer period of time.
After recommissioning the real-time clock has to be set again.
3. Treat device and sensor carefully. Use only in accordance with above specification. (do not throw, hit
against etc.). Protect plug and socket from soiling.