GREISINGER GMH 3692 Скачать руководство пользователя страница 6

H74.0.14.6C-05 

Operating Manual GMH 3692 

page 6 of 12 

4.7  Pop-up clip 

Handling: 

•  Pull at label “open” in order to swing open the pop-up clip. 
•  Pull at label “open” again to swing open the pop-up clip further. 

 

Pop-up clip closed 

 

Pop-up clip at position 90° 

 

Pop-up clip at position 180° 

Function: 

•   The device with a closed pop-up clip can be plainly laid onto a table or attached to a belt, etc. 
•   The device with pop-up clip at position 90° can be set up on a table, etc. 
•   The device with pop-up clip at position 180° can be suspended from a screw or the magnetic holder 

GMH 1300.  

 

Device attached to a belt 

 

 

 

 

Device set up on a table 

 

Device suspended from 

magnetic holder 

GMH 1300 

 

5  Configuration 

 

Some menu points depend on current device settings.  

 

To change device settings, press

 

„Menu“

 

 for 2 seconds. This will activate the configuration menu (main 

display:  “Set”). Pressing 

„Menu“

 

  changes between the menus points, pressing 

 jumps to the 

referring parameters, which can be selected with key 

The parameters can be changed with 

 or 

. Pressing 

„Menu“

 

 again jumps back to the main 

configuration menu and saves the settings. "Quit" 

 finishes the configuration and returns to standard 

measuring operation. 

 

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

1

2

3

4

5

6

ON
OFF

max

Store

CAL

min

Set

Menu

Quit

Содержание GMH 3692

Страница 1: ...Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de As of Version 1 2 Operating Manual GMH 3692 Oxygen meter for oxygen in gases with integrated temperature and pressure m...

Страница 2: ...BRATION OF THE SENSOR 9 7 1 ONE POINT CALIBRATION AL 1 PT 9 7 2 2 3 POINT CALIBRATION AL 2 PT AL 3 PT 9 7 3 EVALUATION OF SENSOR STATE ELE 9 7 4 CALIBRATION INTERVAL INT 10 8 INSPECTION OF THE ACCURAC...

Страница 3: ...esigned and tested in accordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the standard safety measures and spec...

Страница 4: ...the real time clock has to be set again 2 Mains operation with power supply When using a power supply please note that operating voltage has to be 10 5 to 12 V DC Do not apply overvoltage Cheap 12V po...

Страница 5: ...Signals if oxygen and temperature values are stable 5 CAL arrow Signals if automatic calibration is in progress 6 Logg arrow No function 7 Warning sign Signals weak battery or other warning message Di...

Страница 6: ...points depend on current device settings To change device settings press Menu for 2 seconds This will activate the configuration menu main display Set Pressing Menu changes between the menus points p...

Страница 7: ...0 C or 9 0 F 9 0 F The zero point of the temperature measuring is shifted for the entered value This can be used to compensate sensor and instrument deviations OFF No zero adjustment for temperature m...

Страница 8: ...life time also suitable for application with larger CO2 concentrations GOEL 380 Fast responding for low oxygen concentration e g protection atmosphere below 1 max 25 For application without larger CO...

Страница 9: ...xt reference possible references are blinking in the display 3 Second calibration reference Pt 2 The display will show and the referring reference which should be applied A R for ambient air 0 2 for p...

Страница 10: ...cord and display the measuring values GMHKonfig Software for a comfortable configuration of the device e g freeware In case you want to develop your own software we offer a GMH3000 development package...

Страница 11: ...ue too low Wrong sensor connected Check sensor Sensor cable or instrument defect return to manufacturer for repair ERR 7 system error return to manufacturer for repair If BAT is flashing the battery w...

Страница 12: ...Break proof ABS housing Protection class Front side IP65 Dimensions L B H mm Weight Without pressure port 142 x 71 x 26 mm L x B x H approx 160 g incl battery Power supply Current consumption 9V Batt...

Отзывы: