GREISINGER GMH 3610 Скачать руководство пользователя страница 2

H36.0.01.6C-13 

Operating Manual GMH 3610 

page 2 of 12

 

 

Index

 

1

 

DESIGNATED USE ................................................................................................................................................. 2

 

2

 

GENERAL NOTE .................................................................................................................................................... 2

 

3

 

OPERATING AND MAINTENANCE ADVICE ........................................................................................................ 3

 

4

 

SAFETY REQUIREMENTS .................................................................................................................................... 3

 

5

 

DISPLAY AND CONTROL ELEMENTS ................................................................................................................. 4

 

5.1

 

D

ISPLAY ELEMENTS

 ............................................................................................................................................ 4

 

5.2

 

P

USHBUTTONS

 ................................................................................................................................................... 5

 

5.3

 

C

ONNECTIONS

 .................................................................................................................................................... 5

 

6

 

CONFIGURATION .................................................................................................................................................. 6

 

7

 

THE OXYGEN ELECTRODE .................................................................................................................................. 7

 

7.1

 

E

LECTRODE DESIGN

............................................................................................................................................ 7

 

7.2

 

E

LECTRODE 

M

AINTENANCE

 ................................................................................................................................. 7

 

8

 

NOTES TO SPECIAL FUNCTIONS ....................................................................................................................... 8

 

8.1

 

I

NPUT OF ABSOLUTE PRESSURE 

('P.A

BS

') ............................................................................................................. 8

 

8.2

 

Z

ERO 

D

ISPLACEMENT 

(’O

FFSET

’)

 TEMPERATURE

 .................................................................................................. 8

 

8.3

 

B

ASE 

A

DDRESS 

(’A

DR

.’) ...................................................................................................................................... 8

 

9

 

OXYGEN MEASURING - PLEASE NOTE ............................................................................................................. 8

 

9.1

 

A

BSOLUTE ATMOSPHERIC PRESSURE

 ................................................................................................................... 8

 

10

 

CALIBRATION OF THE OXYGEN SENSOR ..................................................................................................... 8

 

10.1

 

1-P

OINT CALIBRATION

 ..................................................................................................................................... 9

 

10.2

 

V

ALUATION OF SENSOR STATE 

(ELEC) ............................................................................................................ 9

 

11

 

ERROR AND SYSTEM MESSAGES ................................................................................................................ 10

 

11.1

 

E

RROR AND 

S

YSTEM 

M

ESSAGES DURING 

O

XYGEN 

C

ALIBRATION

 ..................................................................... 10

 

12

 

THE SERIAL INTERFACE ................................................................................................................................ 11

 

12.1

 

T

HE FOLLOWING INTERFACE FUNCTIONS WILL BE SUPPORTED

:......................................................................... 11

 

13

 

SPECIFICATION ............................................................................................................................................... 12

 

14

 

DISPOSAL INSTRUCTION: .............................................................................................................................. 12

 

 Designated Use 

The GMH 3610 measures the oxygen concentration and the oxygen saturation in liquids.  
For the measurement a external sensor of the type GWO 3600 is required. The measurement takes place at the 
diaphragm head of the external sensor. 
Due to the design of the sensor, the device has to be calibrated at regular intervals (e.g. at fresh air =20.95% oxy-
gen) to get accurate measuring values. If the sensor is used up, this will be detected at calibration and the sensor 
element has to be maintained or replaced before the next measurement. 
 

 

2  General Note 

Read this document carefully and get used to the operation of the device before you use it. Keep this document 
within reach for consulting in case of doubt.  
 

 

Содержание GMH 3610

Страница 1: ...ndort Greisinger Hans Sachs Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Hand held measuring device for dissolved oxygen and temperature as of version V2 1 Operating...

Страница 2: ...AND SYSTEM MESSAGES DURING OXYGEN CALIBRATION 10 12 THE SERIAL INTERFACE 11 12 1 THE FOLLOWING INTERFACE FUNCTIONS WILL BE SUPPORTED 11 13 SPECIFICATION 12 14 DISPOSAL INSTRUCTION 12 1 Designated Use...

Страница 3: ...cordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given...

Страница 4: ...be configured by means of the configuration system p r t Configuration The desired view can be selected by pressing the key Special display elements Min Max Hold shows if a min max or hold value is d...

Страница 5: ...ec start oxygen calibration Set Menu press Set shortly changing of the main display press Menu for 2 sec configuration will activated Store Quit Measurement Hold current measuring value HLD in display...

Страница 6: ...us F All temperature values in degrees Fahrenheit Power off Selection of Power Off Delay 1 120 Power off delay in minutes Device will be automatically switched off as soon as this time has elapsed if...

Страница 7: ...rode sup plies a current No oxygen means no current either The oxygen measurements use up both the silver cathode as well as the lead anode The electrode is subject to ageing Therefore we recommend to...

Страница 8: ...to calibrate oxygen electrode The temperatures of the electrode and of the liquid to be measured have to be identical if necessary wait till temperatures match The Electrode has to be submerged at lea...

Страница 9: ...the diaphragm get wet or be immersed in water The bottle neck opening should only be slightly larger than the electrode diameter make sure to avoid over pressure in the container Note A correctly cal...

Страница 10: ...probe Values below measuring range Are there any values below the measuring range specified measuring value too low Sensor cable defective replace probe System fault switch on again if fault continue...

Страница 11: ...pment package including a universally applicable Windows functions library GMH3000 DLL with documentation can be used by all es tablished programming languages suitable for Windows XP Windows Vista Wi...

Страница 12: ...r GRS3105 see accessories Power supply 9V battery type IEC 6F22 included or additional d c connector internal pin 1 9 mm for external 10 5 12V direct voltage supply suitable power supply GNG10 3000 Po...

Отзывы: