(AL 

ERR.4 

Current too high 

check calibration environment (p.r.t. 'How to 
calibrate oxygen electrode.') 
air bubbles in the diaphragm head? 

(AL 

ERR.6 

timeout: no stable measuring value 

check calibration environment (p.r.t. 'How to 
calibrate oxygen electrode.').  
electrode needs maintenance or has to re-
placed 

12  The serial interface  

All measuring data and settings of the device can be read and changed by means of the serial interface and a suita-
ble electrically isolated interface adapter (GRS3100, GRS3105 or USB3100). 
In order to avoid faulty transmission, we have designed elaborate security measures for interface communication. 

The following 

standard software packages 

are available for data transfer: 

EBS20M  

more channel software to display of all measuring value (channel 1 ... 4) 

EASYCONTROL

:  Universal multi-channel software (EASYBUS-, RS485-, or GMH3000- operation possible) for 

real-time recording and presentation of measuring data in the ACCESS®-data base format. 

In case you want to develop your own software we offer a 

GMH3000-development package 

including: 

 

a universally applicable Windows functions library ('GMH3000.DLL') with documentation, can be used by all 

‘es-

tablished’ programming languages, suitable for: Windows XP™, Windows Vista™

Windows 7™

- Programming examples Visual Basic 4.0, Delphi 1.0, Testpoint 

12.1  The following interface functions will be supported:  

 

Channel 

Dll- 

Code

 

Name / function

 

(Oxygen 

Saturation)

 

(Oxygen Con-

centration)

 

(Temperature)

 

(abs. air 

pressure)

 

Read nominal value 

 

 

 

Set nominal value 

Read system status 

Read min. value 

Read max. value 

 

 

 

12 

Read ID-no. 

 

 

 

174 

Delete min. value 

 

 

 

175 

Delete max. value 

176 

Read min. measuring range 

177 

Read max. measuring range 

178 

Read meas. range unit 

179 

Read meas. range decimal point 

180 

Read meas. range meas. mode 

 

 

 

194 

Set display unit 

 

 

 

195 

Set decimal point of display 

199 

Read meas. type in display 

200 

Read min. display range 

201 

Read max. display range 

202 

Read unit of display 

204 

Read decimal point of display 

 

 

 

208 

Read channel count 

 

 

 

210 

Read electrode state 

 

 

 

216 

Read offset correction 

 

 

 

217 

Set offset correction 

 

 

 

222 

Read power-off delay 

 

 

 

223 

Set power-off delay 

 

 

 

240 

Reset unit 

 

 

 

254 

Read program identification 

 

 

Содержание GMH 3610

Страница 1: ...ndort Greisinger Hans Sachs Str 26 D 93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Hand held measuring device for dissolved oxygen and temperature as of version V2 1 Operating...

Страница 2: ...AND SYSTEM MESSAGES DURING OXYGEN CALIBRATION 10 12 THE SERIAL INTERFACE 11 12 1 THE FOLLOWING INTERFACE FUNCTIONS WILL BE SUPPORTED 11 13 SPECIFICATION 12 14 DISPOSAL INSTRUCTION 12 1 Designated Use...

Страница 3: ...cordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the standard safety measures and special safety advises given...

Страница 4: ...be configured by means of the configuration system p r t Configuration The desired view can be selected by pressing the key Special display elements Min Max Hold shows if a min max or hold value is d...

Страница 5: ...ec start oxygen calibration Set Menu press Set shortly changing of the main display press Menu for 2 sec configuration will activated Store Quit Measurement Hold current measuring value HLD in display...

Страница 6: ...us F All temperature values in degrees Fahrenheit Power off Selection of Power Off Delay 1 120 Power off delay in minutes Device will be automatically switched off as soon as this time has elapsed if...

Страница 7: ...rode sup plies a current No oxygen means no current either The oxygen measurements use up both the silver cathode as well as the lead anode The electrode is subject to ageing Therefore we recommend to...

Страница 8: ...to calibrate oxygen electrode The temperatures of the electrode and of the liquid to be measured have to be identical if necessary wait till temperatures match The Electrode has to be submerged at lea...

Страница 9: ...the diaphragm get wet or be immersed in water The bottle neck opening should only be slightly larger than the electrode diameter make sure to avoid over pressure in the container Note A correctly cal...

Страница 10: ...probe Values below measuring range Are there any values below the measuring range specified measuring value too low Sensor cable defective replace probe System fault switch on again if fault continue...

Страница 11: ...pment package including a universally applicable Windows functions library GMH3000 DLL with documentation can be used by all es tablished programming languages suitable for Windows XP Windows Vista Wi...

Страница 12: ...r GRS3105 see accessories Power supply 9V battery type IEC 6F22 included or additional d c connector internal pin 1 9 mm for external 10 5 12V direct voltage supply suitable power supply GNG10 3000 Po...

Отзывы: