26
OPERATOR PROGRAMMABLE ALARMS
SETTING THE SWING ALARMS
SETTING LEFT SWING ALARM
1. Swing the boom to the desired Left Swing Limit, for example, 325°.
2. Press the operator alarm button (Item 1) twice to access the swing alarm screen.
3. Press the “Left Swing” button. The display will read LEFT SWING 325°.
NOTE: Set the Left and Right Swing Alarms for the system to operate correctly. The red warning
light (Item 3) will flash and the alarm will sound whenever only one of the swing limits is set.
SETTING RIGHT SWING ALARM
1. Move the boom to the desired Right Swing Limit, for example, 35°.
2. Press the “Right Swing” button. The display will read RIGHT SWING 35°.
The red warning light (Item 3) will flash and the alarm will sound whenever the boom swings past
the preset limits.
Pressing the LEFT SWING and RIGHT SWING buttons again will cancel the alarm and the display
will read LEFT SWING OFF RIGHT SWING OFF.
Содержание MicroGuard RCI 514
Страница 30: ...30...