SYSTEM SETUP
OPERATOR PROGRAMMABLE ALARMS
SETTING MINIMUM BOOM ANGLE ALARM
1. Move the boom to the desired minimum angle, in this example, 32°.
2. Press the operator alarm button (Item 1) to access the operator alarm screen.
3. Press the “MIN ANGLE” button. In this example, the display will read MIN ANGLE 32°.
4. The red warning light (Item 3) will flash and the alarm will sound when the boom angle is
below 32°.
5. Press the “MIN ANGLE” button to cancel the alarm and the display will read MIN ANGLE
OFF
SETTING MAXIMUM BOOM ANGLE ALARM
1. Move the boom to the desired maximum angle, in this example 67°.
2. Press the operator alarm button (item 1) to access the operator alarm screen.
3. Press the “MAX ANGLE” button. In this example the display will read MAX ANGLE 67°.
4. The red warning light (item 3) will flash and the alarm will sound whenever the boom angle
is above 67°.
5. Press the “MAX ANGLE” button to cancel the alarm and the display will read MAX ANGLE
OFF.