24
SYSTEM SETUP
OPERATOR PROGRAMMABLE ALARMS
SETTING MAXIMUM BOOM LENGTH ALARM
1. Move the boom to the desired maximum length, in this example 58ft.
2. Press the operator alarm button (Item 1) to access the operator alarm screen.
3. Press the “MAX LENGTH” button. In this example the display will read MAX LENGTH
58FT.
4. The red warning light (Item 3) will flash and the alarm will sound whenever the boom length
exceeds 58ft.
5. Press the “MAX LENGTH” button to cancel the alarm and the display will read MAX
LENGTH OFF
SETTING MAXIMUM TIP HEIGHT ALARM
1. Move the boom to the desired maximum height, in this example, 78ft.
2. Press the operator alarm button (item 1) to access the operator alarm screen.
3. Press the “MAX HEIGHT” button. In this example the display will read MAX HEIGHT 78FT.
4. The red warning light (item 3) will flash and the alarm will sound whenever the boom tip
height exceeds 78ft.
5. Press the “MAX HEIGHT” button to cancel the alarm and the display will read MAX HEIGHT
OFF.