Operation
Power Up Self-Test
Immediately following electrical power up, or by
manually pressing the
TesT
key, the system will
execute a self-test lasting for approximately eight
seconds.
During this time, the numerical display segments and
bar graph segments are all turned on, the audible
alarm will sound, and alarm indicator lights and all
other LED’s are illuminated. The information window
will display the crane model, rating chart number, and
units of measure for length and load.
NOTE: At the end of the self-test, the information window will display “CHECK CONFIGURATION
BEFORE YOU CONTINUE”. Press any key to continue, and then verify the setup of the system to the
current configuration of the crane.
Adjusting Brightness & Contrast
Immediately following self-test and the start up
screen, the information window will display the
brightness and contrast control functions for two
seconds.
Press the key adjacent to either “LED Brightness Up”
or “LED Brightness Down” to increase or decrease
the brightness of the LEDs on the display.
Press the key adjacent to either “Contrast Up”
or “Contrast Down” to increase or decrease the
contrast level of the information window.
Brightness and contrast can be adjusted at any time during normal operation except while operator
alarms are being set.
TEST
SET
MAX
TEST
TEST
SET
MAX